4.
Place back the washer, spring washer and the nut on top of the cable lug.
5.
Tighten the nut with a torque of 20 Nm.
WARNING:
Make sure the cable lug is directly mounted to the battery pole without any
washers or nuts in between.
NOTICE:
When removing the nut and washers from the battery pole, it will become loose.
This is normal. When the cable is connected and the nut and washers back in
place it will be tightened.
NOTICE:
Maximum torque of the battery poles is 20 Nm.
WARNING:
Stacking of multiple cable lugs is possible however we strongly advise against it.
Connection resistance increases which, in time, might lead to excessive heat
generation.