Door operator TVR(FC) 5 / Rev 1.41 ‐ 7
7.3. DIGITAL SETTINGS ‐LIMIT SWITCH AND SAFE‐
TY CIRCUIT FOR DRIVE
Informa on!
Please refer to the control unit’s oper‐
a ng manual for instruc ons on se ng
the end posi ons.
Wiring alloca on
The numbers on the plug are also the wire numbers:
4:
Safety circuit input
5:
RS485B
6:
GND
7:
RS485A
8:
Safety circuit output
9:
7...18 VDC
AVE (absolute value encoder) plug terminal (7‐12)
C.
Thermal element in the drive
D.
Manual emergency control (crank or chain)
E.
Disengagement
Electric interface
A:
AVE plug (absolute value encoder plug)
B:
AVE plug terminal (absolute value encoder plug
terminal)
At the ini al installa on phase, the rota‐
on direc on of the electric motor can
be wrong.
Be prepared to stop the movement to
wrong direc on immediately by using
the STOP bu on.
Interchange two phase conductors to
change the rota on direc on. It is rec‐
ommended to make the change in the
control unit.