Door operator TVR(FC) 5 / Rev 1.41 ‐ 7 

7.3. DIGITAL SETTINGS ‐LIMIT SWITCH AND SAFE‐

TY CIRCUIT FOR DRIVE 

Informa on! 

 Please refer to the control unit’s oper‐
a ng manual for instruc ons on se ng 
the end posi ons. 

Wiring alloca on 

The numbers on the plug are also the wire numbers: 

4:

 

Safety circuit input 

5:

 

RS485B 

6:

 

GND 

7:

 

RS485A 

8:

 

Safety circuit output 

9: 

7...18 VDC 

 

AVE (absolute value encoder) plug terminal (7‐12) 

C. 

Thermal element in the drive 

D. 

Manual emergency control (crank or chain) 

E. 

Disengagement 

 
 

 

 

Electric interface 
A:

 

AVE plug (absolute value encoder plug) 

B:

 

AVE plug terminal (absolute value encoder plug 
terminal) 

At the ini al installa on phase, the rota‐

on direc on of the electric motor can 

be wrong.  
Be prepared to stop the movement to 
wrong direc on immediately by using 
the STOP bu on. 
Interchange two phase conductors to 
change the rota on direc on. It is rec‐
ommended to make the change in the 
control unit. 

Summary of Contents for TVR(FC) 5

Page 1: ...OPERATING AND MAINTENANCE INSTRUCTIONS DOOR OPERATOR TVR FC 5 OVITOR OY SIENITIE 24 FIN 00760 HELSINKI FINLAND Tel 358 0 207 106 600 Fax 358 0 207 106 601 ENG...

Page 2: ...nsidered appropriate for improving the capacity and safety of the door operator The speed and travel of the door determine which gear and limit transmission values should be used Di erent possible tra...

Page 3: ...revent uninten onal star ng of the door operator you must e g lock the main switch of the door operator control system in the 0 posi on 3 2 RATING PLATE Every complete drive unit has two 2 ra ng plate...

Page 4: ...hat this structure will not bend If the moun ng base is not perfectly even the xing lugs of the drive unit could break when the xing screws are ghtened Do not bend gear when ghten ing the xing screws...

Page 5: ...s sealing Make the necessary connec ons A er checking the adjustment and opera on of the limit switches install the cover of the limit switch box in its place Check that the sealing on the gear unit s...

Page 6: ...cumenta on of the control system Limit switches are adjusted as shown in g 6 1 The limit switches are adjusted with the locking screw N and ne adjustment screw M Allen key size 2 5 mm 2 First turn the...

Page 7: ...DC AVE absolute value encoder plug terminal 7 12 C Thermal element in the drive D Manual emergency control crank or chain E Disengagement Electric interface A AVE plug absolute value encoder plug B AV...

Page 8: ...si on Semi annual service and maintenance Check the condi on and adjustment of the slipping clutch Check the ghtness of all xing bolts in the gear unit and the electric motor If a chain is used in pow...

Page 9: ...ate and the part num ber shown in the drawing With the help of the serial num ber it is possible to determine the correct part from the produc on informa on of the gear unit 9 4 FAULT TRACING Very o e...

Page 10: ...unit stops the drive unit Damage to the worm sha or wheel Contact the manufacturer Oil leak from the gear unit frame Mechanical damage in the gear housing Contact the manufacturer Oil leak from the g...

Page 11: ...Door operator TVR FC 5 Rev 1 41 11...

Page 12: ...60335 2 103 EN 13241 A1 EN 12453 EN 12445 EN 12604 EN 12605 EN 12978 A1 SFS Inspecta Ser oin OY has issued a cer cate ascertaining that the manufacturer s quality system meets the require ments of st...