background image

12 ‐Door operator TVR(FC) 5 / Rev 1.41 

10. DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 

DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY 

Ovitor Oy 
Sieni e 24 
00760 Helsinki 
Finland 

Descrip on and iden fica on of the partly completed machinery: 

Door operator TVR(FC) 5 with various limit and gear transmissions

 

The essen al requirements of EC Machinery Direc ve 2006/42/EC have been applied and fulfilled for the above men oned 
machinery to be used with industrial doors, gates and barriers. The relevant technical documenta on has been compiled in 
accordance with Annex VII, Part B of EC Machinery Direc ve 2006/42/EC.  

In addi on the partly completed machinery is in conformity with the EC 2006/95/EC Low Voltage Direc ve LVD, 2004/108/
EC Electromagne c Compa bility EMC and 2002/95/EC the Restric on of the use of certain Hazardous Substances in Electri‐
cal and Electronic Equipment RoHS. 

The above listed products are delivered according to the following standards to the extent to which they may be applicable: 

EN ISO 12100:2010, EN 60204‐1+A1+AC, EN 60335‐1+A11+AC, EN‐55014‐1+A1, EN 61000‐3‐
2+A1+A2, EN 61000‐3‐3, EN 61000‐6‐2, EN61000‐6‐3+A1, EN 61439‐1, EN 61439‐3, EN 60529+A1, 
EN 13241‐1+A1, EN 60335‐2‐103, EN 13241+A1, EN 12453, EN 12445, EN 12604, EN 12605, EN 
12978+A1 
 

SFS‐Inspecta Ser fioin  OY has issued a cer ficate ascertaining that the manufacturer's quality system meets the require‐
ments of standard SFS‐EN ISO 9001:2008 and the general guidelines ABC 200, cer ficate 1229‐06. 

We undertake, in response to a reasoned request, to supply it 

in electronic form

 to the market surveillance authori es with‐

in a reasonable period. 

The party authorized to compile the technical documenta on is: 

Ovitor Oy / Engineering Manager 
Sieni e 24 
00760 Helsinki 
Finland 

The devices are not intended to func on independently but as a part of an electrically operated machine. In the design, con‐
struc on and servicing of the machinery, it must be ensured that the loads to which the door mechanism is subjected do not 
exceed the values given in the instruc on manual of the mechanism, and that the permi ed service life of a door mecha‐
nism  is  no  more  than  12 000  opera ng  hours.  As  regards  the  installa on,  se ngs  and  servicing  of  the  machinery,  the  in‐
struc ons issued by us for the type of installa on in ques on must be observed. 

The partly completed machinery must not be put into service un l the final machinery into which it is to be incorporated has 
been declared in conformity with the provisions of the Machinery Direc ve. 

 

Helsinki, 14th of September 2016 

 

 

_______________ 
Juha‐Ma  Lyhykäinen 
Produc on Manager 
Ovitor Oy 

Summary of Contents for TVR(FC) 5

Page 1: ...OPERATING AND MAINTENANCE INSTRUCTIONS DOOR OPERATOR TVR FC 5 OVITOR OY SIENITIE 24 FIN 00760 HELSINKI FINLAND Tel 358 0 207 106 600 Fax 358 0 207 106 601 ENG...

Page 2: ...nsidered appropriate for improving the capacity and safety of the door operator The speed and travel of the door determine which gear and limit transmission values should be used Di erent possible tra...

Page 3: ...revent uninten onal star ng of the door operator you must e g lock the main switch of the door operator control system in the 0 posi on 3 2 RATING PLATE Every complete drive unit has two 2 ra ng plate...

Page 4: ...hat this structure will not bend If the moun ng base is not perfectly even the xing lugs of the drive unit could break when the xing screws are ghtened Do not bend gear when ghten ing the xing screws...

Page 5: ...s sealing Make the necessary connec ons A er checking the adjustment and opera on of the limit switches install the cover of the limit switch box in its place Check that the sealing on the gear unit s...

Page 6: ...cumenta on of the control system Limit switches are adjusted as shown in g 6 1 The limit switches are adjusted with the locking screw N and ne adjustment screw M Allen key size 2 5 mm 2 First turn the...

Page 7: ...DC AVE absolute value encoder plug terminal 7 12 C Thermal element in the drive D Manual emergency control crank or chain E Disengagement Electric interface A AVE plug absolute value encoder plug B AV...

Page 8: ...si on Semi annual service and maintenance Check the condi on and adjustment of the slipping clutch Check the ghtness of all xing bolts in the gear unit and the electric motor If a chain is used in pow...

Page 9: ...ate and the part num ber shown in the drawing With the help of the serial num ber it is possible to determine the correct part from the produc on informa on of the gear unit 9 4 FAULT TRACING Very o e...

Page 10: ...unit stops the drive unit Damage to the worm sha or wheel Contact the manufacturer Oil leak from the gear unit frame Mechanical damage in the gear housing Contact the manufacturer Oil leak from the g...

Page 11: ...Door operator TVR FC 5 Rev 1 41 11...

Page 12: ...60335 2 103 EN 13241 A1 EN 12453 EN 12445 EN 12604 EN 12605 EN 12978 A1 SFS Inspecta Ser oin OY has issued a cer cate ascertaining that the manufacturer s quality system meets the require ments of st...

Reviews: