ML-32
MevaLite
Intersections
Intersecting walls are formed using
inside corners and standard panels
(Fig. 32.1 - Fig. 32.4). Fillers are
used to make adjustments for
different wall thicknesses.
Steel rails may be required
depending on the filler
configuration (see the "Fillers"
section for additional information
and requirements).
It may be necessary to utilize
threadbar ties in some corner
locations when other tie systems
are used so they can be shifted far
enough to eliminate interferences.
In some cases the need for steel
rails can be avoided by utilizing
rigid inside corners, which can
be tied through the corners
(Fig. 32.5).
Fig. 32.1
R 3'
AF (2" or 3")
IC
AF
R 3'
Tie through 2" or
3"aluminum filler
Fig. 32.2
Fig. 32.3
Fig. 32.4
Fig. 32.5
IC
IC
IC
IC
IC
IC
IC
IC
IC
AF
IC
RIC
AF
AF
R 3'
Wall formwork
Technical Instruction Manual / June 2022