4.1
Important notes
Only use the servo drive BL 4000-C as a built-in device for switch cabinets
Mounting position vertical with supply lines [X9] on top
Mount to control cabinet plate using a fastening strap
Installation free spaces:
Keep a minimum distance of 100 mm to other components each above and underneath the device to
ensure sufficient venting.
For optimal wiring of the motor cable and angle encoder cable on the bottom of the device an
installation free space of 150mm is recommended!
Mounting distance:
The servo drive BL 4000-C may be installed adjacently in one switch cabinet without a gap, proper
usage and installation on a heat-dissipating rear panel provided. Please note that excessive heat may
cause premature aging and/or damaging of the device. In case the servo drives BL 4000-C are
subject to high thermal stress, a mounting distance of 59 mm is recommended!