Electrical installation
Mounting Instructions „Servo drives BL 4000-C“
PRELIMINARY
Version 0.1
Motor Phase U resp. 1
Motor Phase V resp. 2
Motor Phase W resp. 3
BR+
PE
MT+
Motor connector
MT- / HPF_DSL-
Backplane
Control Cabinet
1
4
7
9
2
5
8
3
6
Connector housing
Motor housing
WEIDMÜLLER
BLF 5.08HC/09/180 SN BK BX
at X6
BR-
-
Figure 13:
Motor connection with Motortemperature sensor [X6]
Pin 1 ist labeled in
Figure 3
.
Motor Phase U resp. 1
Motor Phase V resp. 2
Motor Phase W resp. 3
BR+
PE
MT+
Motor connector
MT- / HPF_DSL-
Backplane
Control Cabinet
1
4
7
9
2
5
8
3
6
Connector housing
Motor housing
WEIDMÜLLER
BLF 5.08HC/09/180 SN BK BX
at X6
BR-
-
Figure 14:
Motor connection with Hiperface DSL [X6]
Connect the inner shields and the total shield to the backplane of the Control Cabinet by using appropriate EMC
shield clamps.
Maximum length of unshielded cores 35 mm
Figure 15:
Example of appropriate shield clamps