background image

46

S

CANNER AND 

C

ABLE 

T

ERMINATIONS 

(C

ONTINUED

)

Cable Connector Configuration

The PowerLink cable is terminated with a 5-pin DIN female connector on
one end, and a 6-pin mini DIN male on the other.

Metrologic will supply an adapter cable with a 5-pin DIN male connector
on one end and a 6-pin mini DIN female connector on the other.

According to the termination required, connect the appropriate end of the
adapter cable to the PowerLink cable, leaving the necessary termination
exposed for connecting to the keyboard and the keyboard port on the PC.
The pin assignments are as follows:

PowerLink Cable

Adapter Cable

5-pin Female DIN

5-pin Male DIN

Pin

Function

Pin

Function

1

Keyboard Clock

1

PC Clock

2

Keyboard Data

2

PC Data

3

No Connect

3

No Connect

4

Power Ground

4

Power Ground

5

+5 Volts DC

5

+5 Volts DC

6-pin Male Mini-DIN

6-pin Female Mini-DIN

Pin

Function

Pin

Function

1

Keyboard Data

1

Keyboard Data

2

No Connect

2

No Connect

3

Power Ground

3

Power Ground

4

+5 Volts DC

4

+5 Volts DC

5

PC Clock

5

Keyboard Clock

6

No Connect

6

No Connect

4

2

1

3

6 5

6-Pin DIN, Male

2

1

4

5

3

5-Pin DIN, Female

PowerLink Cable

6-pin Mini Din, Female

Adapter Cable

3

1

2

4

5 6

2

3

5

4

1

5-Pin Din, Male

Summary of Contents for MS7320 InVista Series

Page 1: ...METROLOGIC INSTRUMENTS INC MS7320 InVista Series Installation and User s Guide...

Page 2: ......

Page 3: ...ke Email info uk metrologic com Hampshire RG21 6XG ASIA Singapore Metrologic Asia Pte Ltd Tel 65 6842 7155 No 8 Kaki Bukit Place Fax 65 6842 7166 4 th Floor Email info sg metrologic com Singapore 4161...

Page 4: ...ner Parts 14 Maintenance 14 Cable Cover Installation and Removal 15 Face Plate Removal 15 Scanner Labels 16 Audible Indicators 17 Visual Indicators 18 Failure Modes 19 Power Save Modes and the Multi F...

Page 5: ...of standard features including Automatic scanning operation Firmware updates via Flash ROM EAS deactivation antenna A Programmable Depth of Field Supports multiple interfaces including USB and Keyboa...

Page 6: ...built in power jack 2 1 m 7 cord with short strain relief xxx specifies connection to the host Contact a customer service representative for additional information 54 54002 Keyboard Wedge PowerLink C...

Page 7: ...nental European 45 45592 220V 240V United Kingdom 45 45483 Flex Stand REPLACEMENT PARTS Part Description 46 46624 Everscan Window Face Plate 46 46625 Standard Window Face Plate Other items may be orde...

Page 8: ...PC A software driver and correct configuration settings are also required for proper communication 4 Turn on the host system 5 Scan the Load OCIA Defaults bar code to configure the MS7320 for OCIA com...

Page 9: ...al damage to the scanner 5 Connect the external power supply to the power jack on the PowerLink cable 6 Check the AC input requirements of the power supply to make sure the voltage matches the AC outl...

Page 10: ...e matches the AC outlet 7 Connect AC power to the transformer The outlet should be near the equipment and easily accessible 8 Scan the two bar codes in numbered sequence in order to configure the MS73...

Page 11: ...appropriate interface jack on the scanner An incorrect cable connection can cause communication problems or potential damage to the scanner Plugging the scanner into the USB port of the PC does not gu...

Page 12: ...ink Cable 5 Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet 6 Connect AC power to the transformer The outlet should be near the equipment and easily...

Page 13: ...CES Codes needed for Step 7 on page 8 For RS232 Communication Scan 1 st 9 9 9 9 9 8 Recall Defaults Scan 2 nd 4 1 5 5 5 4 Enable RS 232 For Light Pen Communication Scan 1 st 9 9 9 9 9 8 Recall Default...

Page 14: ...are driver and correct configuration setting are also required for proper communication to occur 4 Turn on the host system 5 Scan the Load 46xx IBM Defaults bar code to configure the MS7320 for RS232...

Page 15: ...PowerLink cables Before continuing verify that the PowerLink cables are connected to the appropriate interface jacks on the scanner An incorrect cable connection can cause communication problems or p...

Page 16: ...nner Contact a Metrologic representative for additional information on the MS6720 1 2 4 8 1 7 Reserve Code 32 Metrologic recommends disabling the beeper on the auxiliary scanner Refer to Beeper Option...

Page 17: ...13 INSTALLATION OF AN AUXILIARY SCANNER Figure 7 Connector Orientation Top Auxiliary Scanner Setup Bottom...

Page 18: ...ip Switch Area u Cable Cover v Stand Foot MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning For the MS7320 gla...

Page 19: ...15 CABLE COVER INSTALLATION AND REMOVAL FACE PLATE REMOVAL Figure 10 Face Plate Removal Figure 9 Installing the Cable Cover left Removing the Cable Cover bottom right...

Page 20: ...the model number date of manufacture serial number and caution information An additional caution label is located under the window faceplate and a label noting the jack interfaces is located under th...

Page 21: ...ure indicator Refer to failure modes page 19 Three Beeps during operation When placing the scanner in program mode the red LED will flash while the scanner simultaneously beeps three times The red and...

Page 22: ...cessfully reads a bar code the red LED will flash and the scanner will beep once If the red LED does not flash or the scanner does not beep once then the bar code has not been successfully read Steady...

Page 23: ...d a motor failure Return the unit for repair at an authorized service center Continuous Razzberry Tone with both LEDs off If upon power up the scanner emits a continuous razzberry tone then the scanne...

Page 24: ...on will wake the scanner from the power save mode see figure 17 This mode is the only power save mode that can be activated by the Multi Function Button see figure 16 This mode s wake up time is sligh...

Page 25: ...etting has been stored in memory The silent no beep tone is also selectable PLACING THE UNIT IN LASER MOTOR OFF POWER SAVE MODE Long 3 seconds depression The Laser Motor Off Power Save Mode is the onl...

Page 26: ...22 SCAN VOLUME BASED ON 100 UPC BAR CODES Figure 18 Scan Area Top View top Side View Bottom Specifications subject to change without notice...

Page 27: ...INIMUM BAR CODE ELEMENT WIDTH BASED ON 100 UPC BAR CODES Figure 19 Depth of Field Top View Minimum Bar Code Element Width A B C D E mm 13 19 26 33 48 mils 5 2 7 5 10 4 13 19 Specifications subject to...

Page 28: ...INIMUM BAR CODE ELEMENT WIDTH BASED ON 100 UPC BAR CODES Figure 20 Depth of Field Side View Minimum Bar Code Element Width A B C D E mm 13 19 26 33 48 mils 5 2 7 5 10 4 13 19 Specifications subject to...

Page 29: ...tand Base Cover Qty 1 c Stand Base Qty 1 d Small Flex Cover Qty 1 e Flex Pole Qty 1 f Large Flex Cover Qty 1 g 8 x 1 00 Wood Screw Qty 4 h 20 x Flat Head Screw Qty 1 i 4 40 x Phillips Head Screw Qty 1...

Page 30: ...26 FLEX STAND INSTALLATION CONTINUED Optional Flex Stand MLPN 45 45483 installation continued from page 25 Figure 25 Figure 26...

Page 31: ...e Fixed Low Density depth of field so that the unit does not scan out beyond the deactivation range Unit CheckPoint Recommended Switch Bank Settings MS7320 Depth of Field Settings MS7320 2 3 4 5 6 on...

Page 32: ...power MS7320 series scanner Use the power supply included with the scanner 3 beeps on power up Non volatile RAM failure Contact a Metrologic Representative if the unit will not hold the programmed co...

Page 33: ...st scan red LED stays on The scanner is configured to support some form of host handshaking but is not receiving the signal If the scanner is setup to support ACK NAK RTS CTS XON XOFF or D E verify th...

Page 34: ...A faulty push button switch Contact a Metrologic Customer Service Representative Keyboard Wedge Only The unit scans the bar code but there is no data Configuration is not correct Make sure the scanner...

Page 35: ...cters show as lower case Computer is in Caps Lock mode Enable the caps lock detect setting of the scanner to detect if the PC is operating in Caps Lock Everything works except for a couple of characte...

Page 36: ...sure the aux port scanner is connected to the MS7320 com port marked Aux port The MS7320 must be programmed to enable the Aux port Aux port scanner powers up but data is not relayed to the host The Au...

Page 37: ...Metrologic System Interfaces PC Keyboard Wedge RS 232 OCIA Light Pen Stand Alone PC Keyboard USB IBM 468x 469x Print Contrast 35 minimum reflectance difference No Characters Read up to 80 data charac...

Page 38: ...IEC 60825 1 1993 A1 1997 A2 2001 EMC FCC ICES 003 EN 55022 Class B ENVIRONMENTAL Operating Temperature 0 C to 40 C 32 F to 104 F Storage Temperature 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relativ...

Page 39: ...ware and the scanner configuration match If the application does not support RS 232 scanners a software wedge program that will take RS 232 data and place it into a keyboard buffer may be needed This...

Page 40: ...programmable functions available in other Metrologic scanners are also available as keyboard wedge functions The following are the most important selectable options specific to the keyboard wedge Keyb...

Page 41: ...AULT OCIA RS 232 LIGHT PEN IBM 46XX KBW USB UPC EAN a a a a a a Code 128 a a a a a a Code 93 a a a a a a Codabar a a a a a a Interleaved 2 of 5 ITF a a a a a a MOD 10 Check on ITF a a a a a a Code 11...

Page 42: ...out None a a a a a a Razzberry Tone on Timeout a a a a a a Three Beeps on Timeout a a a a a a No Beeps on Timeout a a a a a a Enter Power Save Mode 10 mins a a a a a a Blink Power Save Mode a a a a a...

Page 43: ...C E Check Digit a a a a Expand UPC E a a a a a Convert UPC A to EAN 13 a a a a a UPC GTIN 14 Format a a a a a Transmit Lead Zero on UPC E a a a a a a Convert EAN 8 to EAN 13 a a a a a Transmit UPC A N...

Page 44: ...racters a a a STX Prefix a a a ETX Suffix a a a Carriage Return a a a Line Feed disabled by default in KBW a a a Tab Prefix a a a Tab Suffix a a a DE Disable Command a a FL Laser Enable Command a a DT...

Page 45: ...128 a a as code 39 a a a Programmable Code Lengths 7 avail a a a a a a Programmable Prefix Characters 10 avail a a a Suffix Characters a a a Prefixes for individual Code Types a a a Editing a a a a a...

Page 46: ...Pen IBM 46XX KBW USB Aux Baud Rate 38400 a a a a a a Aux parity space a a a a a a Aux data bits 7 a a a a a a Aux stop bits 2 a a a a a a Aux character RTS a a a a a a Aux message RTS a a a a a a Aux...

Page 47: ...model number of the scanner Figure 28 Scanner Interface Ports MS732x 13 OCIA MS732x 13 IBM 46xx Pin Function Pin Function 1 Ground 1 Ground 2 NC 2 RS 232 Transmit Output 3 NC 3 RS 232 Receive Input 4...

Page 48: ...Ground 1 Ground 2 USB D 2 RS 232 Transmit Output 3 USB D 3 RS 232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Input LTPN Source 7 PC 5V V USB 7 N C 8 KB Data 8 LTPN Da...

Page 49: ...on to the host USB PowerLink Cable MLPN 54 54165 Type A Pin Function 1 N C 2 D 3 D 4 Ground PowerLink RS232 AUX Cable MLPN 54 54667 Pin Function 1 Ground 2 RS 232 Transmit Output 3 RS 232 Receive Inpu...

Page 50: ...ing to the keyboard and the keyboard port on the PC The pin assignments are as follows PowerLink Cable Adapter Cable 5 pin Female DIN 5 pin Male DIN Pin Function Pin Function 1 Keyboard Clock 1 PC Clo...

Page 51: ...trologic has been subjected to abuse misuse neglect improper installation or accident nor any damage due to use or misuse produced from integration of the Product into any mechanical electrical or com...

Page 52: ...nce with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does caus...

Page 53: ...le scanner ou le laser Ne regardez jamais directement le rayon laser m me si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous expos...

Page 54: ...5 324 924 5 340 973 5 396 053 5 396 055 5 408 081 5 410 139 5 424 525 5 436 440 5 449 891 5 468 949 5 468 951 5 479 000 5 484 992 5 525 789 5 528 024 5 532 469 5 545 889 5 591 953 5 616 908 5 627 359...

Page 55: ...43 46 H Host 11 I Indicators 17 18 33 Input Voltage 34 Installation 4 5 7 13 Interfaces 4 6 10 28 K Keyboard Type 36 Keyboard Wedge 1 2 5 33 36 44 L Labels 16 LED 14 17 18 28 29 33 Light Levels 34 Lig...

Page 56: ...22 24 33 34 Stand 25 26 33 Storage 34 System Interfaces 33 T Termination 33 Transformers 34 Troubleshooting 28 29 30 31 32 U USB 7 V Ventilation 34 Visual 18 Voltage 4 5 6 7 8 10 11 W Warranty 47 Wei...

Page 57: ...NOTES...

Page 58: ...NOTES...

Page 59: ......

Page 60: ...April 2002 Printed in the USA 0 0 0 2 8 9 6 A...