METRODATA LTD
WCM1100 / WCM3100 / WCM-Serial
Quick Start Guide
76-02-082 Rev D
71 of 75
4.3 SNMP Management
The WCM needs to be configured with the details of the SNMP Network Management
Station before the unit will generate traps, or respond to SNMP polls.
The SNMP parameters are configured using the SNMP menu found under the
Management menu
Metrodata WCM "" Alarms: Major
SNMP
Read community public
Write community public
Trap community public
Managers <menu>
contact Person Metrodata Limited,Fortune House,
Crabtree Office Village,Eversl..
Node name
Location
Stats. <display>
trap Alarms <menu>
First CAPITAL - select item
<escape> - exit menu
4.3.1 Read/Write/Trap Community
To provide a level of security, communities are used to control access to the unit via
SNMP. Separate communities may be configured for Read/Write or Trap access.
4.3.2 Contact Person
The contact person is the SNMP MIB-2 system SysContact parameter, the default setting
is:
Metrodata Limited, Fortune House, Eversley Way, Egham, Surrey, TW20 8RY
The parameter may be up to 255 characters and should be configured to reflect the actual
installation requirements.