3.3 Access the WCM
Initial access to the WCM is made using the Terminal Port on the rear panel of the unit.
The Terminal port defaults to 19200baud, 8bit, No Parity, 1 Stop Bit. The 9 Way D-Type
is configured as a DCE port with standard pinout as shown below:
Pin
Direction
Signal
1
out
DCD
2
out
RXD*
3
In
TXD*
4
In
DTR
5
Signal Ground*
6
out
DSR
7
In
RTS
8
out
CTS
9
no connect
Figure 3.3 Terminal Port Connector Pin Configuration
3.4 Logging onto WCM
The initial access to the WCM must use a terminal connected to the terminal port.
The WCM has a password protected, menu driven user interface. When a management
session is connected to the WCM, the welcome banner will be displayed as shown:
Metrodata WCM1100:
Local connection to “”
Password (‘view’ to view only ) :
or
Metrodata WCM3100:
Local connection to “”
Password (‘view’ to view only ) :
or
Metrodata WCM-Serial: Local connection to “”
Password (‘view’ to view only ) :