background image

 

 

 

N

N

N

V

V

V

F

F

F

-

-

-

2

2

2

0

0

0

0

0

0

S

S

S

E

E

E

/

/

/

P

P

P

D

D

D

 

 

 

K

K

K

I

I

I

T

T

T

 

 

 

 

 

 

E

E

E

t

t

t

h

h

h

e

e

e

r

r

r

n

n

n

e

e

e

t

t

t

 

 

 

E

E

E

x

x

x

t

t

t

e

e

e

n

n

n

d

d

d

e

e

e

r

r

r

 

 

 

w

w

w

i

i

i

t

t

t

h

h

h

 

 

 

R

R

R

e

e

e

m

m

m

o

o

o

t

t

t

e

e

e

 

 

 

P

P

P

o

o

o

w

w

w

e

e

e

r

r

r

 

 

 

 

 

 

U

U

U

s

s

s

e

e

e

r

r

r

s

s

s

 

 

 

M

M

M

a

a

a

n

n

n

u

u

u

a

a

a

l

l

l

 

 

 

Summary of Contents for NVF-200SE/PD KIT

Page 1: ...P P PD D D K K KI I IT T T E E Et t th h he e er r rn n ne e et t t E E Ex x xt t te e en n nd d de e er r r w w wi i it t th h h R R Re e em m mo o ot t te e e P P Po o ow w we e er r r U U Us s se e er r r s s s M M Ma a an n nu u ua a al l l ...

Page 2: ...y rights of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products described in this document without notice NETSYS does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Maximum signal rate derived...

Page 3: ...riber site conversion bridge The NVF 200SE PD uses VDSL technology which support 5M 15 25Mbps per port symmetrical bandwidth over phone wiring with long driver capable of a maximum 1km 0 8km 0 5km 3280ft 2624ft 1680ft The front panel provides LED indicators of power system and interface status Full or half duplex mode of LAN operation is automatically sensed and configured VDSL link rates are conf...

Page 4: ...ble over them DO NOT allow anything to rest on the power cord and do not locate the product where anyone can work on the power cord DO NOT install nor use your device during a thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO NOT use this product near water for example in a wet basement or near a swimming poo...

Page 5: ... 3 TABLE OF CONTENTS 4 CHAPTER 1 UNPACKING INFORMATION 7 1 1 Check List 7 CHAPTER 2 INSTALLING THE BRIDGE 8 2 1 Hardware Installation 8 2 2 Pre installation Requirements 8 2 3 General Rules 9 2 4 Connecting the NVF 200SE and NVF 200PD 9 2 5 Connecting the Line Ethernet Ports 11 CHAPTER 3 HARDWARE DESCRIPTION 13 ...

Page 6: ...ER 4 ABOUT PERFORMANCE 18 4 1 Auto and manual data speed selector description 18 4 2 Distance power relational tables 19 APPENDIX A CABLE REQUIREMENTS 20 APPENDIX B IEEE 802 3AF PSE AND POWERED DEVICE POWER CLASSIFICATIONS 23 APPENDIX C PRODUCT SPECIFICATION 24 APPENDIX C PRODUCT SPECIFICATION 24 APPENDIX D TROUBLESHOOTING 28 APPENDIX E COMPLIANCE AND SAFETY INFORMATION 34 ...

Page 7: ...NVF 200SE PD Power over VDSL Master Slave USER S MANUAL Ver B 4 6 WARRANTY 37 CHINESE SJ T 11364 2006 38 ...

Page 8: ... Power Cord 2 x RJ 45 Ethernet cable 1 x User s Manual CD 4 x Rubber foot Notes 1 Please inform your dealer immediately for any missing or damaged parts If possible retain the carton including the original packing materials Use them to repack the unit in case there is a need to return for repair 2 Power supply included in package is commercial grade Do not use in harsh environments 3 Do not only u...

Page 9: ...cal space and proximity to other network devices that are to be connected Verify the following installation requirements Power requirements 2 x 48VDC 0 4A The bridge should be located in a cool dry place with at least 10cm 4in of space at the front and back for ventilation Place the bridge away from direct sunlight heat sources or areas with a high amount of electromagnetic interference Check if t...

Page 10: ...wered on Make sure to use AC power cord provided with your device as other AC power cord with grounding pin will make the distance reach shorter NVF 200SE PD has one RJ 45 fast Ethernet port which support connection to Ethernet operation The devices attached to these ports must support auto MDIX and auto negotiation or 10Base T OR 100Base TX unless they will always operate at half duplex NVF 200PD...

Page 11: ...NVF 200SE PD Power over VDSL Master Slave USER S MANUAL Ver B 4 10 Figure2 1 NVF 200SE PD line ports straight connection Figure 2 2 NVF 200SE PD line ports crossover connection ...

Page 12: ...f additional wiring Every modular phone jack in the home can become a port on the LAN Networking devices can be installed on a single telephone wire that can span within 1km or 500m depends on speed between the two farthest points Figure 2 3 Figure 2 3 Master Slave Ethernet extender with remote power point to point application 2 Use only twisted pair cable with RJ 45 connectors that conform to Eth...

Page 13: ...et 2 Line port must use 22 26 gauge phone wiring we do not recommend 28 gauge or above 3 We advise using Category 3 4 5 cables for cable bridge or router connections to avoid any confusion or inconvenience in the future when you attached to high bandwidth devices 4 Be sure phone wiring has been installed before NVF 200SE and NVF 200PD powered on ...

Page 14: ...L Ver B 4 13 Chapter 3 Hardware Description This section describes the important parts of the bridge It features the front panel and rear connectors 3 1 NVF 200SE NVF 200PD Detailed View Figure 3 1 NVF 200SE detailed view Figure 3 2 NVF 200PD detailed view ...

Page 15: ...f it has signal from its Ethernet RJ 45 port if it is either providing or receiving power and if there is line signal on the line port Table 3 1 Table 3 1 Description of the bridge front interface Interface Connector Type Description Line RJ 45 Terminal Block For connecting to NVF 200SE PD bridge Ethernet RJ 45 For connecting to the networking device for NVF 200SE For connecting to the networking ...

Page 16: ...ver Ethernet LED for NVF 200PD only Green Off The power injector has not detected the power splitter On The device has a good Ethernet connection Link Blinking The device is transmitting receiving data Activity Eth Ethernet LED Green Off The LAN is not connected On For NVF 200SE the device power feeding is ready For NVF 200PD the device is remote power link good PoV Power over VDSL Green Off The d...

Page 17: ...wing figure shows the rear connectors Figure 3 4 Figure 3 4 Rear connectors of NVF 200SE PD respectively At quick glance you can see the DIP switch setting at default mode where it is in auto speed and interleave delay is set to 0ms as shown in Figure 3 5 Figure 3 5 DIP switch setting ON OFF ...

Page 18: ...delay to 0ms Both pin 3 and pin 4 have to switch to OFF To config the interleave delay to 100ms Pin 4 must be switch ON while pin 3 is OFF To config the interleave delay to 150ms Pin 3 must be switch ON while pin 4 is OFF To config the interleave delay to 300ms Both pin 3 and pin 4 have to switch to ON Table shows the summary of DIP switch configuration Table 3 3 Table 3 3 DIP Switch Configuration...

Page 19: ...f the phone cable length If the cable length is unsure then auto selection of the data speed at the default setting is recommended Power must be unplug before changing the data speed then power on and wait for VDSL to link again at the correct data speed function Speed mode limitation 5M 5M mode within 1km 3280ft 15M 15M mode within 800m 2624ft 25M 25M mode within 500m 1640ft Note 1 We recommend p...

Page 20: ... 1 Table 4 1 Distance power relational tables Distance m Speed Mb PoV Link Power W max Output Voltage V Output Current A 30 25 OK OK 11 67 12 0 97 100 25 OK OK 11 67 12 0 97 200 25 OK OK 11 69 12 0 97 300 15 OK OK 11 7 12 0 98 400 15 OK OK 9 36 12 0 78 400 5 OK OK 10 12 0 83 500 15 OK OK 8 12 0 67 500 5 OK OK 8 12 0 67 600 5 OK OK 6 12 0 5 Note If you would like to know overall power consumption N...

Page 21: ... for data transmission purposes power supply uses pins 4 5 and ground uses pins 7 8 Table A 1 Table A 1 RJ 45 Ethernet Connector Pin Assignments MDI MDI X PIN Signal Media Dependant interface Signal Media Dependant interface cross 1 TX Transmit Data RX Receive Data 2 TX Transmit Data RX Receive Data 3 RX Receive Data TX Transmit Data 4 48V NVF 200PD only 48V NVF 200PD only 5 48V NVF 200PD only 48V...

Page 22: ... 200SE PD Power over VDSL Master Slave USER S MANUAL Ver B 4 21 Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable Figure A 3 Pin Assignments and Wiring for an RJ 45 Crossover Cable ...

Page 23: ...eight pins VDSL signal use pins 4 and 5 for data transmission A telephone cable is shown below Figure A 4 A B Figure A 4 Telephone cable The A and B connectors on the rear of the bridge are RJ 45 connectors These connectors are wired identically The RJ 45 connectors have eight positions two of which are wired The bridge uses the center two pins The pin out assignment for these connectors is presen...

Page 24: ...vice Power Classifications Class Usage Minimum Power Levels Output at the PSE Maximum Power Levels at the Powered Device 0 Default 15 4W 0 44 to 12 95W 1 Optional 4 0W 0 44 to 3 84W 2 Optional 7 0W 3 84 to 6 49W 3 Optional 15 4W 6 49 to 12 95W 4 Reserved for Future Use Treat as Class 0 Reserved for Future Use A class 4 signature cannot be provided by a compliant powered device ...

Page 25: ...t using single pair phone cable Supports 1 x RJ 45 for fast Ethernet port with power injector NVF 200PD only Supports 1 x DIP switch for line speed and interleave delay setting NVF 200SE only Supports Auto 5 15 25Mbps speed mode and full duplex for VDSL port Supports long packet size up to 1536 bytes Supports PBO Power Back Off function for NVF 200PD Data and Remote Power work on the same phone li...

Page 26: ...200PD only 1 x RJ 45 for single pair VDSL line port 1 x Terminal block for VDSL line port 1 x DIP switch for line speed and interleave delay setting NVF 200SE only 2 x Power jack for 48V power adapter NVF 200SE only Power Protection OTP Over Temperature Protection OVP Over Voltage Protection OCP Over Current Protection Robust short circuit protection VDSL and Ethernet surge protection System Manag...

Page 27: ...00 kHz 3 9MHz Power Injector NVF 200PD Using CAT 5 UL standard twisted pair phone cable Max 15 4W within 500m 1640ft Max 12W within 600m 1968ft Max 8W within 800m 2624ft Max 5 5W within 1000m 3280ft Note Real output power depends on PD side power splitter power transmission efficiency Power Injector mode Mid span mode support connecting to Class 0 1 2 3 of PD side power splitter Distance Reach 25M...

Page 28: ...200SE PD Power over VDSL Master Slave USER S MANUAL Ver B 4 27 Humidity 10 to 90 non condensing Dimensions NVF 200SE 146mm x 97mm x 33mm 5 75 x 3 82 x 1 30 NVF 200PD 169mm x 106mm x 33mm 6 65 x 4 17 x 1 30 ...

Page 29: ...ly Check the power cord with another device If these measures fail to resolve the problem have the unit power supply replaced by a qualified distributor Note Don t use other AC to DC power adapter 2 Symptom Link indicator does not light up green after making a connection Cause Network interface ex a network adapter card on the attached device network cable or switch port is defective Solution 2 1 ...

Page 30: ... mode setting and phone wire length Therefore if NVF 200SE can t detect NVF 200PD over phone cable while both power on this will cause the link to fail 3 2 Please check phone cable must be Cat5 22 26 gauge with twisted pair and without rust and the length is not over 1km 3 3 Please check the correct DIP switch setting that must follow up phone cable length limitation Note Phone cable must meet CAT...

Page 31: ...o NVF 200PD 6 Symptom Power splitter cannot power feeding to networking device Cause NVF 200PD built in power injector output is limited by phone cable length Solution Make sure to follow the product specification of NVF 200PD power injector output by differential cable length 7 Question We using NV 200SE PD kits and the end point device NVF 200PD when touch gives them a shock Answer NVF 200SE wil...

Page 32: ... want connect to NVF 200PD please make sure the networking device has built in power splitter PD function if yes please connect it directly if not please connect between NVF 200PD and networking device through a power splitter PD side our PD provide three models 5V 9V 12V and how to choose PD model which depend on networking device DC input requirement ...

Page 33: ...er cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly Transmission Mode The default method of selecting the transmission mode for Ethernet port is 10 100Mbps Ethernet while line port is for 5 15 25Mbps speed mode Therefore if the link signal is disrupted e g by unplugging the network cable and plugging it back in ...

Page 34: ...plementing the new changes one step at a time Ensure that cable distances and other physical aspects of the installation do not exceed recommendations System Integrity As a last resort verify the switch integrity with a power on reset Turn the power to the switch off and then on several times If the problem still persists and you have completed all the preceding diagnoses then contact your dealer ...

Page 35: ...he equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 The equipment and the receiver should be connected to outlets on separate circuits 4 Consult the dealer or an experienced radio television technician for help Changes or...

Page 36: ...essible Caution Use only the power supply included with this product In the event the power supply is lost or damaged In the United States use only with CSA certified or UL listed Class 2 power supply rated 2 x 48Vdc 0 4A or above IN Europe use only with CE certified power supply rated 2 x 48Vdc 0 4A or above Do not use this equipment near water for example in a wet basement Avoid using a telephon...

Page 37: ...ations Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at owner s expense CE Mark Warning This is a class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effec...

Page 38: ... way attributable to improper installation or to alteration or repairs made or performed by any person not under control of the original owner The above warranty is in lieu of any other warranty whether express implied or statutory including but not limited to any warranty of merchantability fitness for a particular purpose or any warranty arising out of any proposal specification or sample We sha...

Page 39: ...MANUAL Ver B 4 38 Chinese SJ T 11364 2006 有 毒 有 害 物 质 或 元 素 部件名称 铅 Pb 汞 Hg 镉 Cd 六价铬 Cr VI 多溴联苯 PBB 多溴二苯醚 PBDE 结构壳体 电路组 电源供应器 线材 包装及配件 表示该有毒物质在该部件所有均质材料中的含量均在 SJ T 11364 2006 标准规定的限量要求以下 表示该有毒物质至少在该部件的某依均质材料中的含量超出 SJ T 11364 2006 标准规定的限量要求 上述规范仅适用於中国法律 ...

Reviews: