6 Technical specifications
94
RS-232
8 pin PS/2 – type
2400 baud ÷ 115200 baud
* The charging time and the operating hours are given for batteries with a nominal
capacity of 2500mAh
6.2 Measurements
Note:
In order to get resolution and accuracy specified in this section, measuring data
should be observed by PowerView (Waveform Snapshoot or On-Line View). PowerQ4
display resolution is reduced due to screen space constraints and enhanced visibility of
presented measurements (larger screen fonts and space between measurements).
6.2.1 General description
Max. input voltage (Phase – Neutral):
1000 V
RMS
Max. input voltage (Phase – Phase):
1730 V
RMS
Phase - Neutral input impedance:
6 M
Ω
Phase – Phase input impedance:
6 M
Ω
AD converter
16 bit 8 channels,
simultaneous sampling
Reference temperature
23
°
C ± 2 °C
Temperature influence
60 ppm/
°
C
NOTE:
Instrument has 3 voltage ranges. Range has to be chosen according to the
network nominal voltage, according to the table bellow.
Nominal phase voltage: U
Nom
Recommended Voltage range
50 V ÷ 110 V
Voltage Range 1: 50 V ÷ 110 V (L-N)
110 V ÷ 240 V
Voltage Range 2: 110 V ÷ 240 V (L-N)
240 V ÷ 1000 V
Voltage Range 3: 240 V ÷ 1000 V (L-N)
Nominal phase-to-phase voltage: U
Nom
Recommended Voltage range
86 V ÷ 190 V
Voltage Range 1: 89 V ÷ 190 V (L-L)
190 V ÷ 414 V
Voltage Range 2: 190 V ÷ 414 V (L-L)
415 V ÷ 1730 V
Voltage Range 3: 240 V ÷ 1730 V (L-L)
NOTE:
Assure that all voltage clips are connected during measurement and logging
period. Unconnected voltage clips are susceptible to EMI and can trigger false events. It
is advisable to short them with instrument neutral voltage input.
6.2.2 Phase Voltages
U
pRms
, p: [1, 2, 3, 4, N]
Measuring range
Resolution Accuracy
Crest factor
Range 1: 20 V
RMS
÷ 150.0 V
RMS
10
mV
Range 2: 50 V
RMS
÷ 360 V
RMS
Range 3: 200 V
RMS
÷ 1500 V
RMS
100 mV
0.2 %
U
RMS
1.5 min
U
pRms(1/2)
p: [1, 2, 3, 4, N], AC+DC
Measuring range
Resolution Accuracy
Crest factor
Range 1: 20 V
RMS
÷ 150.0 V
RMS
10 mV
0.5 %