3 Operating the instrument
28
harmonic wave and is denoted with amplitude and a phase shift (phase angle) to a
fundamental frequency signal. See 5.1.8 for details.
3.5.1 Meter
By entering HARMONICS menu from MAIN MENU the HARMONICS – METER tabular
screen is shown
(see figure below)
. In this screens voltage and current harmonics and
THD are shown.
Figure 3.19: Harmonics meter table.
Description of symbols and abbreviations used in METER screens are shown in table
bellow.
Table 3.17: Instrument screen symbols and abbreviations
Show currently displayed channel.
Current recorder status
RECORDER is active
RECORDER is busy (retrieving data from memory)
RECORDER is not active
Current instrument time
RMS
True effective value U
Rms
and I
Rms
THD
Total harmonic distortion THD
U
and THD
I
hn
n: 0..50
n
th
harmonics voltage Uh
n
or current Ih
n
component
Table 3.18: Keys function
Waveform snapshoot:
Hold measurement on display
Save held measurement into memory
Represent harmonics as % of first harmonic RMS value
Represent values in RMS quantities (Volts, Ampere)