![METREL PowerQ4MI 2592 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/metrel/powerq4mi-2592/powerq4mi-2592_instruction-manual_1778984007.webp)
1 Introduction
7
•
PowerView
is a companion PC Software which provides easiest way to
download, view and analyze measured data or print.
o
PowerView analyzer exposes a simple but powerful interface for
downloading instrument data and getting quick, intuitive and descriptive
analysis. Interface has been organized to allow quick selection of data
using a Windows Explorer-like tree view.
o
User can easily download recorded data, and organize it into multiple sites
with many sub-sites or locations.
o
Generate charts, tables and graphs for your power quality data analyzing,
and create professional printed reports
o
Export or copy/paste data to other applications (e.g. spreadsheet) for
further analysis
o
Multiple data records can be displayed and analyzed simultaneously.
Merge different logging data into one measurement, synchronize data
recorded with different instruments with time offsets, split logging data into
multiple measurements, or extract data of interest.
1.2 Safety
considerations
To ensure operator safety while using the PowerQ4 instrument and to minimize the risk
of damage to the instrument, please note the following general warnings:
The instrument has been designed to ensure maximum operator safety. Usage
in a way other than specified in this manual may increase the risk of harm to the
operator!
Do not use the instrument and/or any accessories if there is any damage visible!
The instrument contains no user serviceable parts. Only an authorized dealer
can carry out service or adjustment!
All normal safety precautions have to be taken in order to avoid risk of electric
shock when working on electrical installations!
Only use approved accessories which are available from your distributor!
Instrument contains rechargeable NiMh batteries. The batteries should only be
replaced with the same type as defined on the battery placement label or in this
manual. Do not use standard batteries while power supply adapter/charger is
connected, otherwise they may explode!
Hazardous voltages exist inside the instrument. Disconnect all test leads,
remove the power supply cable and switch off the instrument before removing
battery compartment cover.
In hot (> 40 °C) environment the battery holder screw might reach maximum
allowed temperature for metal part of handle. In such environment it is advisable
not to touch the battery cover during or immediately after the charging.
Maximum voltage between any phase and neutral input is 1000 V
RMS
. Maximum
voltage between phases is 1730 V
RMS
.
Always short unused voltage inputs (L1, L2, L3) with neutral (N) input to prevent