Metaphaser Command List
– DC Version – UDP
Command Name
Transmit
Unit Metaphaser Response Range
CMD_OUTPUT_LEVEL_READ
00 08 00 B2 00 00 00 00
%
00 08 00 B2 00 00 00 xx
00 to 64
CMD_OUTPUT_LEVEL_SET
00 08 00 B3 00 00 00 xx
%
--
00 to 64
CMD_OUTPUT_LEVEL_LIMIT_READ
00 08 00 B4 00 00 00 00
%
00 08 00 B4 00 00 00 xx
00 to 64
CMD_OUTPUT_LEVEL_LIMIT_SET
00 08 00 B5 00 00 00 xx
%
--
00 to 64
Example: (For
“CMD_OUTPUT_LEVEL_READ” Response) 00 08 00 B2 00 00 00 5A **All Bytes are in HEX
(O
r “CMD_OUTPUT_LEVEL_SET” Transmit)
00 08 00 B3 00 00 00 5A **All Bytes are in HEX
00 08=String length 00=Chan 1 B2 (or B3)=Command 00=Reserved 00 00 5A=Data (90% Output Level)
Metaphaser Command List
– Strobe Version – UDP
Command Name
Transmit
Unit Metaphaser Response Range
CMD_DC_AMPS_READ
00 08 00 B6 00 00 00 00
mA
00 08 01 B6 00 00 xx xx
14 to 0FA0
CMD_DC_AMPS_SET
00 08 00 B7 00 00 xx xx
mA
--
14 to 0FA0
CMD_MAX_DC_AMPS_READ
00 08 00 BA 00 00 00 00
mA
00 08 01 BA 00 00 xx xx
14 to 0FA0
CMD_MAX_DC_AMPS_SET
00 08 00 BB 00 00 xx xx
mA
--
14 to 0FA0
CMD_PULSE_AMPS_READ
00 08 00 BE 00 00 00 00
mA
00 08 01 BE 00 00 xx xx
64 to 9C40
CMD_PULSE_AMPS_SET
00 08 00 BF 00 00 xx xx
mA
--
64 to 9C40
CMD_MAX_PULSE_AMPS_READ
00 08 00 C2 00 00 00 00
mA
00 08 01 C2 00 00 xx xx
64 to 9C40
CMD_MAX_PULSE_AMPS_SET
00 08 00 C3 00 00 xx xx
mA
--
64 to 9C40
CMD_STROBE_PULSEWIDTH_READ
00 08 00 C6 00 00 00 00
uSec
00 08 01 C6 00 00 xx xx
02 to EA60
CMD_STROBE_PULSEWIDTH_SET
00 08 00 C7 00 00 xx xx
uSec
--
02 to EA60
CMD_MAX_STROBE_PULSEWIDTH_READ 00 08 00 CA 00 00 00 00
uSec
00 08 00 CA 00 00 xx xx
02 to EA60
CMD_MAX_STROBE_PULSEWIDTH_SET
00 08 00 CB 00 00 xx xx
uSec
--
02 to EA60
CMD_PULSEWIDTH_DELAY_READ
00 08 00 CE 00 00 00 00
uSec
00 08 00 CE 00 00 xx xx
06 to EA60
CMD_PULSEWIDTH_DELAY_SET
00 08 00 CF 00 00 xx xx
uSec
--
06 to EA60
CMD_STROBE_PERIOD_READ
00 08 00 D2 00 00 00 00
uSec
00 08 00 D2 00 00 xx xx
14 to EA60
CMD_STROBE_PERIOD_SET
00 08 00 D3 00 00 xx xx
uSec
--
14 to EA60
CMD_MIN_STROBE_PERIOD_READ
00 08 00 D6 00 00 00 00
uSec
00 08 00 D6 00 00 xx xx
14 to EA60
CMD_MIN_STROBE_PERIOD_SET
00 08 00 D7 00 00 xx xx
uSec
--
14 to EA60
CMD_OUTPUT_READ
00 08 00 DE 00 00 00 00
Enab/Dis 00 08 00 DE 00 00 00 xx
01 or 00
CMD_OUTPUT_SET
00 08 00 DC 00 00 00 xx
Enab/Dis
--
01 or 00
CMD_MODE_READ
00 08 00 E1 00 00 00 00
DC/Strobe 00 08 00 E1 00 00 00 xx
03 or 04
CMD_MODE_SET
00 08 00 DF 00 00 00 xx
DC/Strobe
--
03 or 04
CMD_TRIGGER_SOURCE_READ
00 08 00 E4 00 00 00 00
Int/Ext
00 08 00 E4 00 00 00 xx
01 or 00
CMD_TRIGGER_SOURCE_SET
00 08 00 E2 00 00 00 xx
Int/Ext
--
01 or 00
CMD_KEYPAD_READ
00 08 00 E7 00 00 00 00
Enab/Dis 00 08 00 E7 00 00 00 xx
01 or 00
CMD_KEYPAD_SET
00 08 00 E5 00 00 00 xx
Enab/Dis
--
01 or 00
CMD_TRIGGER_POLARITY_READ
00 08 00 EA 00 00 00 00
Rise/Fall 00 08 00 EA 00 00 00 xx
01 or 00
CMD_TRIGGER_POLARITY_SET
00 08 00 E8 00 00 00 xx
Rise/Fall
--
01 or 00
Ex
ample: (For “CMD_DC_AMPS_READ” Response) 00 08 00 B6 00 00 0F A0 **All Bytes are in HEX
(O
r “CMD_DC_AMPS_SET” Transmit) 00 08 00 B7 00 00 0F A0 **All Bytes are in HEX
00 08=String length 00=Chan 1 B6 (or B7)=Command 00=Reserved 00 0F A0=Data (4000 mA DC)
Metaphase LED Light Engine
Model#: MP
-
LE1007
www.metaphase-tech.com
Summary of Contents for Metaphaser MP-LE1007
Page 19: ...DC Version Metaphaser MetaBOSS DC Mode Tab Metaphase LED Light Engine Model MP LE1007 ...
Page 21: ...Strobe Version Metaphaser MetaBOSS DC Mode Tab Model MP LE1007 Metaphase LED Light Engine ...
Page 22: ...Strobe Version Metaphaser MetaBOSS Strobe Mode Tab Metaphase LED Light Engine Model MP LE1007 ...
Page 23: ...Strobe Version Metaphaser MetaBOSS Firmware Tab Metaphase LED Light Engine Model MP LE1007 ...
Page 27: ...Metaphaser Trigger Input Equivalent Schematic Metaphase LED Light Engine Model MP LE1007 ...
Page 35: ......