Configuration for
Ø100/150
only for natural gas G20/G25
(Not for LPG!)
See Section 5.3.2.1 Wall Duct Ø100/150
For each additional 90° bend, add 1 metre of vertical flue
or remove 1 metre horizontally.
For each additional 45° bend or less, add 0.5 metre of vertical flue or remove 0.5 metre of horizontal flue.
The baffle is removed from the appliance in this configuration.
There must always be a minimum of a 1 metre length of flue vertically above the fireplace before a 90° bend may
be used.
Reducer on the fireplace
METALOTERM
USDVK 10 13
Vertical outlet:
METALOTERM
USDVC2 -10
Ø100/150
Horizontal outlet:
METALOTERM
USDHC 5
Ø100/150