G815
D
May 05
16
Easy setup
Easy setup must be performed to set the opening and closing travel times.
NOTE
Easy setup only sets the limits and force/speed, and is fully automated; professional
setup also offers slow-stopping and pedestrian access, but is not fully automated. It is an
automated procedure that sets the gate leaf travel times based on the detection of the
limits of travel. Gate stops or limit switches must be used. Gate stops must be positioned
such that the gates rest firmly against them at each limit of travel.
CAUTION
During this procedure the gates must be attended. Movement can be stopped
at any point by pressing the RESET button. The gates must be in the midway position
before starting this procedure.
To initiate the procedure, press RESET, press P1/SET for 1 second while the yellow LED
is flashing. The following steps are performed automatically:
1.
Detects whether one motor or two is fitted
2.
Sets pedestrian opening on M1 leaf to half way
3.
Checks for presence of photocells (or a jumper) on PHO terminal; e-stop (or a
jumper) on STP terminal
4.
Begins to open the M1 leaf.
NOTE
If the M2 leaf moves first, or if the leaf begins to close first, press RESET to
stop the movement and then reverse the motor wiring accordingly. Start this setup
procedure again.
5.
Begins to open M2 leaf 1 second after the M1 leaf.
6.
After 3 seconds of opening, gates stop moving.
7.
Closes the M2 leaf fully, closes the M1 leaf fully, stopping hard against the closed
stops (if fitted) or stopping using a limit switch.
8.
Opens the M1 and M2 leaves fully, stopping hard against the open-stops (if fitted)
or stopping using a limit switch.
9.
Pauses 3 seconds at fully open.
10.
Closes fully, slowing down to around 1/3 speed, after 90% of the travel time.
In summary the procedure is: open 3 seconds, close fully, open fully, wait 3 seconds, close
fully.