G815
D
May 05
22
no change, Step 12 selects the ‘stop when interrupted, move when clear’ option:
11.
Only press P1/SET to close the gates if:
a. photocell is obstructed when closing then reverse immediately, and;
b. photocell is obstructed when opening do nothing
12.
Only press P2/RADIO to close the gates if:
a. photocell is obstructed when closing then stop and only reverse when obstruction
is removed, and;
b. photocell is obstructed when opening then stop and continue opening when
obstruction is removed
13.
The two leaves will close fully, slowing down at the time previously chosen
The following steps are for pedestrian access only:
14.
Only press P1/SET if Pedestrian Access is required. The M1 leaf will begin
opening.
Press P1/SET at the time where the Pedestrian Access wing is at the desired open
position. The leaf will close fully and the unit will exit Professional Setup.
15.
If Pedestrian Access is not required, press P1/SET and P2/RADIO
simultaneously
NOTE
The professional setup procedure will time out after four minutes if abandoned.
Testing the gate operation
Test the operation of all controls and safety devices.
Allow for the effect of weather. Wind or water will make the gates more difficult to move. If
the sensitivity is set to react to extremely light obstructions then the gates may fail to open
or close fully. After adjustment, check that the force on an obstruction at the far end of the
gate leaf does not exceed 150N (15 kg). Use a spring balance.