Delay compensation
Input and Output delay are strongly dependent on the Hardware. This implies that if one records a
single source with two different devices at the same time, one will get two slightly out-of-phase tracks.
This is explained by the fact that every device has its own circuitry and different components.
To minimize this issue, Pro Tools implemented an Auto Delay Compensation feature which will
automatically shift the recording depending on the Hardware used.
The IOM-H-PT64 module was made to emulate three different Digidesign interfaces and match every
interface’s actual input/output latency (within a margin of maximum 3 samples). This chart shows what
latency to expect for different setups. Analog/Digital modules latencies are already included in these
measures.
Emulation Mode
Routing
44k1/48k 88k2/96k 176k4/192k
None
Input
-
2* smpl.
2* smpl.
2* smpl.
Output
-
2* smpl.
2* smpl.
2* smpl.
192IO
Input
From AD8D
65 smpl.
65 smpl.
65 smpl.
Output
To DA8
24 smpl.
14 smpl.
15 smpl.
HDIO
Input
From AD8D
16 smpl.
12 smpl.
11 smpl.
Output
To DA8
56 smpl.
21 smpl.
21 smpl.
HD MADI
Input
From MADI
6 smpl.
6 smpl.
7 smpl.
Output
To MADI
5 smpl.
5 smpl.
7 smpl.
* Added to the other modules used
For the delay compensation to be working, it must be enabled in the ProTools software (Options ->
Delay Compensation).
Emulation Mode
Configures which Digidesign interface the IOM-H-PT64 module will emulate in Pro Tools. This option
does not affect the Hapi routing or preamps, it will just set the Input/Output Delays as seen above.
When set to None, Pro Tools will see the module as an HD MADI, but Hapi will use the minimum
latency. Therefore, Delay Compensation will not be accurate on Pro Tools in this mode.
Error AAE -6116
When Hapi is configured to follow the Sample Rate asked by Pro Tools, an AAE -6116 error might
happen when opening a project with a new Sample Rate. If it happens, click OK to close the error
information. Then, when trying to play the file, the error might show again. After clicking OK, the error
should not appear again.
If this issue is too frequent, a way to avoid it is to disable the Auto-Follow option in Setup -> Formats
and change the Sample Rate on Hapi by hand. This should reduce the probability of getting such an
error.
Summary of Contents for Hapi MKII
Page 1: ...Hapi MKII User Manual Revision 0 01 19 03 2021...
Page 12: ...www merging com hapi Page 12 HAPI MKII User Manual HAPI MKII Block Diagram...
Page 17: ...www merging com hapi Page 17 HAPI MKII User Manual IOM H AKDG8D AKDG8DP block diagram...
Page 20: ...www merging com hapi Page 20 HAPI MKII User Manual IOM H AKD8D AKD8DP block diagram...
Page 23: ...www merging com hapi Page 23 HAPI MKII User Manual IOM H AD8D AD8DP block diagram...
Page 32: ...www merging com hapi Page 32 HAPI MKII User Manual IOM H ADA8S ADA8P block diagram...
Page 93: ...www merging com hapi Page 93 HAPI MKII User Manual HAPI HORUS Setup Examples...
Page 94: ...www merging com hapi Page 94 HAPI MKII User Manual...
Page 95: ...www merging com hapi Page 95 HAPI MKII User Manual...
Page 96: ...www merging com hapi Page 96 HAPI MKII User Manual...
Page 97: ...www merging com hapi Page 97 HAPI MKII User Manual...
Page 98: ...www merging com hapi Page 98 HAPI MKII User Manual...
Page 102: ...www merging com hapi Page 102 HAPI MKII User Manual Block Diagram...