OPERATION
31
Fuse Holder (b)
Fuse Holder (c)
5 amp Hour Meter
A‑RED/
GRN
5 amp Fuel Pump
Relay
A‑RED/
BLK
B‑RED/
ORN
B‑RED/
PNK
15 amp CAN/Main
Remote
C‑RED
20 amp IAC Boost
Bypass
C‑RED/
GRN
D‑RED/
PPL
D‑RED/
BLU
15 amp Constant
Power
E‑RED
20 amp Coil Power
E‑RED/
GRN
F‑RED/
BLU
F‑RED/
YEL
5 amp Accessories
G‑PPL
20 amp Fuel Injectors G‑RED/
GRN
H‑PPL/
WHT
H‑RED/
WHT
In an emergency, if you cannot locate and correct the cause of the high
current draw, and you must operate the engine; perform the following:
1. Turn "OFF" or disconnect all accessories connected to the engine and
instrumentation wiring and reset the circuit breaker.
2. If the breaker remains open, electrical overload is still present. Inspect
the electrical system.
The power trim system is protected by a 10 amp fuse in the power trim RED
(Hot) wire.
a
7416
a -
10 amp fuse