8
4. Technical data
3.7/11 C2 (Rx)
*
7.4 C2 (Rx)
3.7 C1 (Rx)
Charging power Mode 3 [kW]
3.7 / 11
7.4
3.7
Rated voltage U
N
[V]
230 / 400
AC ±10 %
230
AC ±10 %
230
AC ±10 %
Rated frequency f
N
[Hz]
50
Rated current l
nA
[A]
16
32
16
Maximum backup fuse [A]
16
32
16
Protection degree
Enclosure: IP 54
Charging connector with installed flap: IP 44
Protection class
II
Dimensions (H × W × D) [mm]
280 × 260 × 110
Weight [kg]
5
Rated insulation voltage U
i
[V]
500
Rated impulse withstand voltage U
imp
[kV]
4
Rated current of charging points circuit I
nC
[A]
16, 1 ph / 3 ph
32, 1 ph
16, 1 ph
Rated conditional short-circuit current of charging
points circuit I
cc
[kA]
10
Rated diversity factor RDF
1
Pollution degree
3
Overvoltage category
III
Types of system earthing
TN / TT
Installation
Outdoor or indoor
Stationary or movable
Stationary
Usage
AEVCS
External design
Wall installation
EMC classification
A+B
Mechanical impact protection
IK 08
Terminals for supply
line
Terminals
5 × 6
3 × 10
3 × 6
Clamping range [mm²]
rigid 5 × 6
flexible 5 × 4
rigid 3 × 10
flexible 3 × 6
rigid 3 × 6
flexible 3 × 4
Tightening torque [Nm]
max. 0.8
max. 1.8
max. 0.8
Charging cable
Type 2, 20 A,
3 ph, 5 m
Type 2, 32 A,
1 ph, 5 m
Type 1, 20 A,
1 ph, 5 m
Standard
IEC 61851, DIN IEC / TS 61439-7
*)
The Compact 3.7/11 C2 (Rx) can be operated single-phase or three-phase.