12
5.8 Connecting the supply line
Fig.: 10. Connection of the supply line
f
Strip the supply line and remove wire insulation.
f
Connect the cores of the supply line to the terminal
block according to the label.
f
Check the individual cores for proper connection and
screws for tight seating.
5.9 Configuring the charging current
The charging current can be configured via the disconnect
terminals XT1 and XT2.
XT1
XT2
Charging current
3.7/11 C2 (Rx) 7.4 C2 (Rx) 3.7 C1 (Rx)
Open Open
10 A
16 A
10 A
Open Close
13 A
20 A
13 A
Close Open
16 A
28 A
16 A
Close Close
-
32 A
-
The settings will only be accepted following a device
restart.
The configuration options may vary for the different devices.
5.10 Changing the colour setting
of the indicator light
The standard colour setting of the indicator light can be
changed by rewiring the auxiliary contact of the contactor
(A).
f
Disconnect the wires at the auxiliary contact (A), termi-
nals 32 and 44.
f
Swap the wires.
f
Connect the wires to the auxiliary contact (A), terminals
32 and 44.
Torque: 1.2 Nm
5.11 Checking the device
Testing in accordance with IEC 60364 (DIN VDE 0100
in Germany) and national regulations
During the first commissioning and at the
specified maintenance intervals, carry out a test of the
charging station in accordance with IEC 60364 (DIN VDE
0100 in Germany) and the corresponding, valid national
regulations. For testing in accordance with the standards,
the test can be carried out using the MENNEKES test box
and test equipment. The MENNEKES test box simulates
communication with the vehicle. Test boxes are available
from MENNEKES as an accessory.
f
Before releasing the device, carry out a test in accord-
ance with the standard.
Test box operating manual.
Fig.: 11. Changing the colour setting of the indicator light
A