HIGH ALTITUDE INSTALLATIONS
For installations from 610-1370 meters (2000-4500 ft.) the orifice sizes (DMS) for natural gas are #43 Front/#46
rear and for propane gas are #55 front/#54 rear. See data plate for additional information. For high altitude instal-
lations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the installer
must convert the unit to adjust for varying altitudes, the information sticker must be filled out by the installer and ad-
hered to the appliance at the time of conversion.
«Cet appareil est equipé pour des altitudes compries entre 0 et 2000 pieds (0-610 m) seule-
ment»
This appliance has been converted for use at an altitude of ______________
Orifice size _______________
Manifold Pressure ________________
Input (Btu/h)_______________ Fuel Type _______________________
Date of conversion _________ Converted by _____________________
«Cet appreeil a été converti au ____
Injecteur ________
Pression à la tubulure d'alimentation _____________
Déoit calorifique _______________»