Advanced BIT
Built In Test (BIT) and Status Fields
9.1
Internal health and status are monitored and communicated in both hardware and
software. The ultimate indication of a fatal problem is a hardware BIT signal on the user
connector which is mirrored in the software BIT field as the masterFail flag. This flag is
thrown as a result of a number of instantly fatal conditions (known as a “hard” failure) or
a per
sistent serious problem (known as a “soft” failure).
Soft errors are those which must
be triggered multiple times within a specified time window to be considered fatal. Soft
errors are managed using a digital high-pass error counter with a trigger threshold.
The masterStatus flag is a configurable indication as determined by the user. This flag is
asserted as a result of any asserted alert signals which the user has enabled.
The hierarchy of BIT and Status fields and signals is depicted here:
BITstatus Field
masterFail
hardwareError
hardwareBIT Field
powerError
hardwarePowerBIT Field
inpPower
inpCurrent
inpVoltage
fiveVolt
threeVolt
twoVolt
twoFiveRef
sixVolt
grdRef
environmentalError
hardwareEnvironmentalBIT Field
pcbTemp
comError
comBIT Field
serialAError
comSerialABIT Field
transmitBufferOverflow
receiveBufferOverflow
framingError
breakDetect