MEMOLUB
®
24VDC-PLC
PLC-Controlled
ML24VDC-PLC-0205
Copyright © 2005 PLI, LLC All Rights Reserved
Lubricator Installation Instructions
1. To open, place the lubricator
upright on flat surface. Press
firmly and turn locking ring
counter-clockwise while
holding the ribbed surface.
2. Remove the paper, disk-
shaped label from the
replacement cartridge and fill
in the "Start Date" and
"Change Date".
3. Carefully squeeze air out of
the cartridge until grease be-
gins to emerge from the outlet.
4. Place the cartridge on the
inlet of the red housing.
5. Place the clear housing
assembly over the lubricant
cartridge and red housing.
6. Holding the locking ring
by its ribbed surface, turn it
clockwise until it clicks into
the locked position.
8. Screw the MEMOLUB®
HPS lubricator onto the
Power-Through MEMO.
Note: If necessary, prime the
MEMOLUB® HPS with a
hand grease gun (
grease
cartridges only).
1. Program the volume of
lubricant output by inserting
the stroke-limiting washers.
2. Install the Power-Through
Memo fitting, either direct or
remote mounted.
3. Screw the MEMOLUB®
24VDC-PLC on the Power-
Through Memo fitting.
4. The MEMOLUB® 24VDC-
PLC must be connected to a PLC
for its power supply. The PLC
determines the frequency of
output cycles.
(PLC Not Included)
Lubricant Cartridge Change Out Instructions
Grease Cartridges Only
3. Hold the cartridge with the
outlet facing up. Carefully re-
move the cartridge plug. Turn
the red housing over and gently
place it on the outlet of the car-
tridge.
4. While holding the cartridge
and red housing together, flip
the assembly over and hold
the cartridge in place.
Oil Cartridges Only
SAFETY PRECAUTIONS
* Warning:
Lower red housing contains
a loaded spring. Do not open.
* Use only factory pre-filled cartridges
and battery packs with MEMOLUB®
lubricator.
PLI, LLC
www.memolub.com
PLI, LLC * P.O. Box 044051 * 1509 Rapids Dr. * Racine, WI 53404
Telephone: 800-635-8170 * Fax: 262-637-4090
MEMOLUB
®
HPS User's Guide
Page 39 of 39
PLI, LLC