Mellanox Grid Director 4700 Installation Manual
85
management ports on the rear of the Chassis. Both types of management network can be
connected simultaneously.
To connect to the Management port Ethernet Interface:
1.
Connect the end of the management cable with the single RJ-45 connector to the
Management port on the 4700.
2.
Connect the end of the cable with Ethernet connector to the appropriate devices/network.
To connect to the Management port Serial Interface:
1.
Connect the end of the management cable with the single RJ-45 connector to the
Management port on the 4700.
2.
Connect the end of the cable with the DB-9 serial connector to a PC or a console. The
PC/console must support VT100 terminal emulation and should be equipped with terminal
emulation software such as HyperTerminal or ProComm Plus.
3.
Make sure that your PC/console terminal emulation software is configured to communicate
with the 4700 via hardware flow control. Configure the baud rate and character format of
the PC terminal emulation program to match these RS-232 management port default
characteristics:
38,400 baud
Eight data bits
One stop bit
No parity
Flow Control – None