![Meler Cantho Instruction Manual Download Page 28](http://html1.mh-extra.com/html/meler/cantho/cantho_instruction-manual_1767116028.webp)
FOCKE MELER GLUING SOLUTIONS
4-4
MELTER OPERATION
In case of overheating the system cuts off inmediately the damaged element.
After three minutes if the failure continues all the system will be shut down.
After repairing the failure the system starts heating normally.
Operational pressure display and adjustment
In these equipments the air pressure with which the pneumatic control of
the pusher piston cylinder device works with is shown on the pressure gauge
located on the base of the melter/applicator. The pressure must be adjusted
according to the application needs.
Warning
:Never surpass 6 bar of pressure
To regulate the pressure, pull the handle out and turn the regulator clockwise
(+) or counterclockwise (-) as needed.
+ -
+ -
Code
Source
Actions
Heating
Temp. OK and Main machine signal
Err 0
Grille broken sensor
only grille off
off
Err 1
Tank broken sensor
only grille off
off
Err 100
Grille overheating
all components off
off
Err 101
Tank overheating
all components off
off
Summary of Contents for Cantho
Page 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Page 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Page 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Page 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Page 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Page 64: ......