MELTER OPERATION
4-3
MA-5168-ENG
ADHESIVE MELTER CANTHO
They are also equipped with LEDs indicating equipment connection/
disconnection and standby function connection/disconnection (3).
Displaying the temperature for each component
The temperature may be displayed for each component (grille and tank) by
selecting the component with the cursor.
Press the uo-down arrow until the desired component is displayed.
After 10 seconds, the display will return to the default component (the grille)
If you wish to keep the component displayed permanently, press and hold the
up-down arrow for 2 seconds while selecting the chosen element.
Alarm displays
The melter equipments tell the user when a malfunction has occurred in
the unit, sending warning messages that may be seen on the control panel
display.
When an alarm appears, the control unit takes a series of steps to protect the
unit. Simply correct that malfunction and the control unit will reactivate the
equipment functions.
Standby function does not generate any alarm.
If a temperature sensor is broken, the system heats all the elements except
the one where the failure is located.
160
160 160
160
Err
Err 001
001
LED display
Component heating
Component staus
constantly lit
constant
low temperature
blinking slowly
as need (acoording to PID parameters) temperature near set point
blinking rapidly
programming or display
change in set point values
off
not heating
temperature reached
LED display
On/off
Standby
constantly lit
turned off unit
function activated
blinking slowly
descativation programmed for the
current day
activation programmed for the
current day
blinking rapidly
activation/desactivation programming
mode
activation/desactivation program-
ming mode
off
unit in operation
function desactivated
simultaneous intermittence from leds of
pump activation and main machine signal timing in process, once the tank has reached its set point temperature
160
160 160
160
3
Summary of Contents for Cantho
Page 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Page 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Page 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Page 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Page 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Page 64: ......