T . A L A R M :
6 0 m
L E V E L
D E T E C T O R
T Y P E
N O : O f f
I F
N O = O f f >
N C
I F
N O = O n
>
N O
The value displayed corresponds to the increase in real temperature
over the set point temperature permitted without activating the alarm
message.
4. Use the up arrow for element selection to advance to the next screen.
5. Exit the special menu using the down arrow for element selection and
the grid temperatures will once again be displayed.
All the special menu values will be saved.
Changing the parameters on the LOGO controller
On the LOGO controller located inside the panel, the type of connection for the
level signal can be selected (activation of the piston and discharge valve):
Off -> Normally closed (NC)
On -> Normally open (NO)
Select the type of connection according to the device used. To modify the type
of connection, access the controller inside the panel.
Warning:
Risk of electric shock. Carelessness may cause injury or death.
The LOGO screen displays the parameters that can be modified, as well as
some information about them:
1. Press the ESC key for a few seconds until the cursor appears below the
first parameter ‘60’ (T. ALARM).
2. Use the right and left arrows to move to the parameter you wish to
modify. If you press ‘OK’, the parameter is displayed in negative (light
value over a dark background).
3. Change the T.ST value with the up-down arrows.
4. Once modified, press the OK key to validate the value. To exit the edit
mode, press the ESC key.
20
20
_
_
_
_
_
_
Summary of Contents for Cantho
Page 1: ...ADHESIVE MELTER CANTHO INSTRUCTIONS MANUAL MA 5168 ENG 251019 GLUING SOLUTIONS ...
Page 38: ...FOCKE MELER GLUING SOLUTIONS 4 14 MELTER OPERATION This page is intentionally left blank ...
Page 44: ...FOCKE MELER GLUING SOLUTIONS 5 6 MAINTENANCE This page is intentionally left blank ...
Page 49: ...ELECTRICAL DRAWINGS 7 1 MA 5168 ENG ADHESIVE MELTER CANTHO 7 ELECTRICAL DRAWINGS ...
Page 50: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 52: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWINGS This page is intentionally left blank ...
Page 62: ...FOCKE MELER GLUING SOLUTIONS 9 10 SPARE PART LIST This page is intentionally left blank ...
Page 64: ......