background image

T. 1300 222 445 | www.melec.com.au

For further information about our Warranties please go to: 

melec.com.au/legal/warranties 

TECHNICAL INFORMATION

Zigbee to DALI+0/1-10V 2 in 1 Converter

Function introduction

Important: 

Read All Instructions Prior to Installation

Product Data



Safety & Warnings














 under DALI mode







Operation

1) Select

 DALI or 0/1-10V Output Using 

 Switch 10

Note: 

3) Select DALI Address or Group Control Mode Using D Switch 7

Note: 

4) 

Note: here device type is selected as DIM as an example, please select your correct DALI device type.

Select the DALI Group to be Controlled Using D  Switches 2-6 

Note: 1)

DIP 

2)

 

3)

 

up

Note:

2) Select DALI Device Type (DT6/DT8 Color Type) to be Controlled Using DIP Switches 8-9

DA/-

L

L1

DA/+

Prog.

N

N

ML-ZIG-010D

ZigBee to DALI+0/1-10V

2 in 1 Converter with Relay

110-240V ~ 50/60Hz 

Max. load: 5A Resistive

1E4

 

 

DALI

0/1-10V

DALI Add.

μ

•tc=75°C
20T 50

1.6A LED

•  Zigbee to DALI+0/1-10V 2 in 1 converter based on Zigbee 3.0 
• 

Zigbee signal inpit 110-240VAC power input, DALI signal output ro DALI line or 0/10V signal output

•  Max. 5A relay and metering function
• 

Compatible with universal Zigbee gateway or hub products 

• 

Can directly pair to a compatible Zigbee remote via Touchlink

• 

Compatible with universal Zigbee remotes

•  Supports self-forming Zigbee network without coordinator
•  Supports find and bind mode to bind a Zigbee remote
•  Supports Zigbee green power and can bind max. 20 Zigbee green power remotes
•  DALI signal or 0/1-10V signal output selectable by DIP switches
•  Built-in DALI bus power supply, no extra DALI bux PS required
•  With max. 50mA DALI bus power current output
•  Able to supply control current up to 25 DALI control devices
•  DALI DT6 or DT8 device type selectable by DIP switch under DALI mode 
• 

Color control according to DALI specifications of Device Type 8

• 

Color type: Tc, XY coordinates, RGBW selectable by DIP switches

•  DALI address control mode or group control mode selectable by DIP switch
•  DALI address (00-63) to be controlled by DIP switches
•  DALI group (0-15) to be controlled by DIP switches
• 

Control 1 DALI Group of devices or 1 DALI address on DALI line

• 

Control all devices on DALI via broadcast

SAFETY & WARNINGS

•  DO NOT set the DIP switches with power applied to the device.
•  DO NOT install with power applied to device.
•  DO NOT expose the device to moisture.
•  The product shall be installed and serviced by a licensed electrician
•  IP20. Please avoid the sun and rain. When installed outdoors, please ensure it is mounted in a water-proof enclosure
•  Always be sure to mount this unit in an area with proper ventilation to avoid overheating.
•  Please check if the output voltage of any LED power supplies used complies with the working voltage of the product.
•  Never connect any cables while power is on always assure correct connections to avoid short circuit before switching on.
•  Please ensure that the cable is secured tightly to the connector.
•  Follow all relevant electrical and safety standardS (AS3000).
•  All components must not be mechanically stressed
•  Be careful not to damage or destroy conductive paths on the circuit board
• 

Correct electrical polarity must be observed as the wrong polarity may destroy the product and is not covered under warranty

•  Damage by corrosion will not be honoured as a material defect claim. It is the user’s responsibility to provide suitable protection against 

corrosive agents such as moisture, condensation and other harmful elements

Summary of Contents for ML-ZIG-010D

Page 1: ...tput DALI Output 0 1 10V Output relay Environment Others Power Signal DALI PS current DALI current consumption Current Switching voltage Current Operating temperature Relative humidity Dimensions 110 240Vac Zigbee 2 4Hxz Max 50mA Max 4mA Max 20mA 110 240vac Resistive 5A LED 1 6A 20 50 c 8 80 80x36x20 5mm Rated impulse withstand voltage 2500V IP rating IP20 Overvoltage category II PTI 175V Glow wir...

Page 2: ...IP switch under DALI mode Color control according to DALI specifications of Device Type 8 Color type Tc XY coordinates RGBW selectable by DIP switches DALI address control mode or group control mode selectable by DIP switch DALI address 00 63 to be controlled by DIP switches DALI group 0 15 to be controlled by DIP switches Control 1 DALI Group of devices or 1 DALI address on DALI line Control all ...

Page 3: ...3 4 5 6 7 8 9 10 Switch down Note please first select output signal by the DIP switch 2 Select DALI Device Type DT6 DT8 Color Type to be Controlled Using DIP Switches 8 9 DO NOT set the DIP switches with power applied to the device DO NOT install with power applied to device DO NOT expose the device to moisture Safety Warnings Control all devices on DALI line via broadcast Waterproof grade IP20 DI...

Page 4: ...ght flashe timeout re L N L N WIRING DIAGRAM WHEN 0 1 10V OUTPUT SELECTED Zigbee Lighting Device Step 2 Set another device remote or touch panel into network pairing mode and pair to the network refer to their manuals Step 3 Pair more devices and remotes to the network as needed refer to their manuals Step 4 Bind the added devices and remotes through Touchlink so that the devices can be controlled...

Page 5: ...0 240V 50 60Hz Max load 5A Resistive 1E4 DALI 0 1 10V DALI Add μ 20T 50 1 6A LED DA L L1 DA Prog N N ML ZIG 010D ZigBee to DALI 0 1 10V 2 in 1 Converter with Relay 110 240V 50 60Hz Max load 5A Resistive 1E4 DALI 0 1 10V μ 20T 50 1 6A LED t again Step 2 Set the remote or touch panel target node into find and bind mode and enable it to find and bind initiator please refer to corresponding remote or ...

Page 6: ...L L1 DA Prog N N ML ZIG 010D ZigBee to DALI 0 1 10V 2 in 1 Converter with Relay 110 240V 50 60Hz Max load 5A Resistive 1E4 DALI 0 1 10V DALI Add μ 20T 50 1 6A LED DA L L1 DA Prog N N ML ZIG 010D ZigBee to DALI 0 1 10V 2 in 1 Converter with Relay 110 240V 50 60Hz Max load 5A Resistive 1E4 DALI 0 1 10V DALI Add μ tc 75 C 20T 50 1 6A LED 8 WHEN DALI OUTPUT SELECTED their by the or d a zigbee p When D...

Page 7: ... Diagram when 0 1 10V Output Selected 3 Safely locate the purple and grey or pink 1 10V dimming cables Connect to your 1 10V dimming system 4 Use suitable fixing methods to fix the ML ZIG 010 D onto the fitting e g by screwing the controller down onto the fitting or using adhesive on bottom surface B 5 Ensure you use suitable sealant glands to keep the IP rating 6 Refit the back plate and ensure a...

Reviews: