- 17 -
2CD-7713v1/GDB5F40
Instructions Manual
( )
(
)
6
General-purpose I/O connector J10
●
(
)
Connector
: 53426-0710 Molex
●
(
)
Conformity connector : 51103-0700 Molex: accessories
●
(
)
Conformity contact:
: 50351-8100 Molex: accessories
●
(
)
Conformity crimp tool : 57295-5000 Molex
Acceptable wire
: AWG28
AWG22
●
〜
(
φ
〜φ
)
Coating
1.15
1.8
(
)
Contact insertion side
No.
Signal name
Description
Direction
−
(
)
1
R.GND
Return GND of each signal for +24 V interface
(
)
2
I
FSSTOP
Immediate stop signal of both X-axis and Y-axis B contact
3
I
IN0
General-purpose input 0
4
I
IN1
General-purpose input 1
5
O
OUT0
General-purpose output 0
6
O
OUT1
General-purpose output 1
7
N.C
Connection is prohibited.
−
The default values of the FSSTOP signal is ACTIVE OFF input B contact .
・
(
)
(
)
The pulse is not output if it doesn't connect into the status of NORMAL ON
GND connection
when signal unused.
( )
(
)
7
Extend I/O communication connector J11
●
(
)
Connector
: 1565994-4 e-CON:Tyco Electronics
●
(
)
Conformity cable : CE-66-01/IO-A03 0.3 m, It is not an accessories.
(
)
: CE-66-02/IO-A10 1 m, It is not an accessories.
No.
Signal name
Description
Direction
(
)
1
I/O
+RS485 EXT
(
)
+ side signal of the Extend I/O serial data Line driver positive logic
(
)
2
I/O
-RS485 EXT
(
)
- side signal of the Extend I/O serial data Line driver negative logic
3
S.G
Signal GND for Extend I/O
−
4
F.G
Frame GND is connected with case.
−
Number of Extend I/O that can be connected from J11 is one unit.
・
J10
1
1
1
2
3
4
5
6
7
1
J11