- 18 -
2CD-7713v1/GDB5F40
Instructions Manual
2-5. Input and output specifications
1
Output specifications
( )
Circuit
Description
Signal name
OUT0, OUT1
Interface
+24 V
+24 V
voltage
Nch transistor
Output method
OUT0,OUT1
Open collector output
←
Lamp ON/OFF
Max. 30 mA
(
)
Photocoupler
etc.
(
=
)
ON
: 30 mA Vce
1 V or less
Output current
R.GND
(
=
)
50 mA Vce
2 V or less
OFF : 0.1 mA or less
Common for OUT0 and OUT1
Output
1 ms or less
(
→
、
→
)
response time
ON
OFF
OFF
ON
Photocoupler isolation
Insulation
(
)
Between internal circuits and external circuits.
2
Input specifications
( )
Circuit
Description
Sensor faction
●
Signal name
ORG, NORG, CWLM, CCWLM *1
+24 V
(
)
can be supplied by 24V for the sensor: Up to 100mA
24 V
2 V or less
〜
±
General-purpose faction
(
)
Polyswitch
Max. 100 mA
●
IN0 , IN1
Sensor faction
●
Other
6.8 K
Ω
●
Photocoupler
R.GND
FSSTOP
*1
Interface
+24 V
+24 V
voltage
Input
●
General-purpose
Ω
faction
6.8 K
impedance
FSSTOP
●
ON/OFF
ON : 2.5 mA or more
6.8 K
Ω
Photocoupler
R.GND
level
OFF : 0.8 mA or less
Input
1 ms or less
The sensor system is each axis and a common specification.
(
→
、
→
)
response time
ON
OFF
OFF
ON
(
)
The general purpose faction and additionally FSSTOP is excluded.
Photocoupler isolation
Insulation
(
)
Between internal circuits and external circuits.
1 The default value of each axis LIMIT signal and the FSSTOP signal is the ACTIVE OFF input
B contact .
*
(
)
(
)
The pulse is not output if it doesn't connect it in the state of NORMAL ON
GND connection
when it is signal unused.
・
(
)
The logic of B contact input can be switched to A contact input. Applied function