Hardware

3.3

Digital Input/Output 

The ME-5001 has totally six 8 bit digital I/O ports (subdevice 0..5). In 
single operation mode, the subdevices can be configured independently 
of one another, as input or output. The direction of the ports is defined 
by software. After powering up, all the ports are configured as inputs.

Diagram 4: Wiring of digital inputs/outputs

Please read chapter 4.1.1 from page 23 for programming the different 
operating modes.

DIO_0..7

DIO_8..15

DIO_16..23

DIO_24..31

GND_PC

R

T

Subdevice 1

8

In/Out

R

T

Subdevice 0

8

In/Out

3.3 V/5 V

R

T

Subdevice 3

DIO_32..39

DIO_40..47

8

Subdevice 4

8

Subdevice 5

8

In/Out

R

T

Subdevice 2

8

In/Out

Level switching  

3.3 V

5 V

5V

Summary of Contents for ME-5000 series

Page 1: ...Meilhaus Electronic Manual ME 5001 1 1E Plug on Board for ME 5000 series with up to 48 Digital I Os alternatively Frequency Measurement and Pulse Generator...

Page 2: ...s Electronic assumes no responsibility for its use any infringements of patents or other rights of third parties which may result from use of this manual or the product Meilhaus Electronic assumes no...

Page 3: ...2 3 Fitting the Plug on Board 12 3 Hardware 15 3 1 Block Diagram 15 3 2 ME 5001 cPCI PCIe 16 3 3 Digital Input Output 17 3 3 1 Digital Inputs 18 3 3 2 Digital Outputs 18 3 3 3 External Trigger 18 3 4...

Page 4: ...s Page 4 Meilhaus Electronic Appendix 29 A Specifications 29 B Pinout 32 B1 25 pin D Sub ST1 33 B2 Additional Sockets ST2 ST3 34 C Accessories 35 D Technical Questions 36 D1 Hotline 36 D2 Service addr...

Page 5: ...boards of the ME 5000 series require a base board of the ME 5000 series and will be plugged onto these and extend the functio nality of the base boards Depending on the PC platform the plug on board...

Page 6: ...into the D sub socket and secured using both screws Only in this way can the board be expected to function properly 1 1 2 Improper Use Plug on boards must never be operated outside the PC Never connec...

Page 7: ...h the help of the following list Your package should contain the following parts 48 bit digital I O board used as a plug on board for the base boards of the ME 5000 series Manual in PDF format on CD D...

Page 8: ...ailable for measuring the frequency and duty cycle of rectangular signals max 5 5 MHz Pulse generator The concept of the configurable subdevices allows subdevice 1 to be employed as a rectangular wave...

Page 9: ...on page 23 Interrupt For interrupt handling in the bit pattern change mode see chapter 4 2 on page 27 Customer specific versions of the firmware are available on request 1 4 System Requirements The M...

Page 10: ...Rev 1 1E Manual ME 5001 Introduction Page 10 Meilhaus Electronic...

Page 11: ...C Temp Meilhaus ME iDS Use the Meilhaus Intelligent Driver System ME iDS for programming your new data acquisition hardware For installation and operation of the driver system please follow the docume...

Page 12: ...order to be able to insert the plug on board Here you should observe the procedure as described in the manual for your PC system 2 Make sure that electrostatic discharges cannot take place through the...

Page 13: ...Manual ME 5001 Rev 1 1E Meilhaus Electronic Page 13 Initial Operation Diagram 1 Fitting the plug on boards...

Page 14: ...Rev 1 1E Manual ME 5001 Initial Operation Page 14 Meilhaus Electronic...

Page 15: ...he base board Base Board ME 5001 RT Logic level selectable 3 3 V 5 V Buffer Buffer Buffer Buffer RT DIO_0 7 FI_0 7 DIO_8 15 FO_0 7 DIO_16 23 DIO_24 31 RT RT DIO_32 39 DIO_40 47 Subdevice 0 Subdevice 1...

Page 16: ...n the following chapters you will learn more about the external wiring of the individual subdevices Chapter 4 from page 21 describes the ope ration modes and the programming 3 2 ME 5001 cPCI PCIe Diag...

Page 17: ...e direction of the ports is defined by software After powering up all the ports are configured as inputs Diagram 4 Wiring of digital inputs outputs Please read chapter 4 1 1 from page 23 for programmi...

Page 18: ...ed directly to the PC See chapter 4 2 on page 27 3 4 Frequency Input Output The concept of the configurable subdevices of the ME 5000 series gives you the option of using individual subdevices with an...

Page 19: ...put 3 5 External Interrupt If required you can also monitor the bit pattern of the digital inputs The bit pattern change mode is available on the ME 5001 As soon as the specified event occurs an inter...

Page 20: ...the subdevices 0 3 The termination circuits are effectively protected against overload by the combination of current limiting and thermal shutdown with automatic return to service 3 6 2 Logic Level M...

Page 21: ...under www meilhaus com download Other details such as the assignment of the subdevices and device specific arguments may be found in the help file in the help file format under Windows chm which you...

Page 22: ...he bit pattern change mode see chapter 4 2 1 starting on page 27 Subdevice type subtype I Os ID of the configuration Subdevice 0 DIO FI Digital input output DIO Single 8 bit bi directional 0 Frequency...

Page 23: ...g mode All subdevices are of type ME_TYPE_DIO subtype ME_SUBTYPE_SINGLE The configuration is done separately for each subdevice Diagram 6 Digital input output in single operating mode Please observe t...

Page 24: ...iDS manual and the ME iDS help file chm carefully prior to programming You can open both of these documents through the ME iDS Control Center or through the Windows Start menu Two variables are introd...

Page 25: ...figures for the ME 5001 are Tmax asym 32 5 s 0 03 Hz Tmax sym 65 s 0 015 Hz The wiring of the frequency inputs outputs can be found in chapter 3 4 on page 18 4 1 2 1 Frequency Measurement With the fr...

Page 26: ...tput rectangular signals with a variable duty cycle at frequencies of up to 5 5 MHz and with a resolution of 1 tick On the ME 5001 all 8 pulse generator channels FO_0 7 are addressed as subdevices of...

Page 27: ...manual and the ME iDS help file chm for the procedure You can open both of these documents through the ME iDS Control Center or through the Windows Start menu 4 2 1 Bit pattern Change In the bit patt...

Page 28: ...function meIOIrqStart bit 2 is monitored for a fal ling edge and bit 7 for a rising edge A rising edge now is to arrive at bit 7 so that an interrupt is issued and in the interrupt status value bit b2...

Page 29: ...Subdevice 0 5 16 bit bidirectional Operating modes Single Software triggered reading writing Interrupt Monitoring the digital ports for a change in the bit pattern External trigger inputs DIO_0 47 Ex...

Page 30: ...1 ns 5 5 MHz 32 5 s 0 03 Hz 65 s 0 015 Hz Duty cycle Variable depending on T Measurable in steps of 1 tick Resolution 1 tick 15 15 ns Accuracy 15 15 ns Operating modes Single Measured quantity criteri...

Page 31: ...via base board 3 3V 5V Current consumption additional to base board 0 50 0 9A full load Board dimensions without mounting bracket and connector base board requires its own slot 120mm x 100mm Connectio...

Page 32: ...DIO_16 23 Digital input output subdevice 2 DIO_24 31 Digital input output subdevice 3 DIO_32 39 Digital input output subdevice 4 DIO_40 47 Digital input output subdevice 5 FI_0 7 Frequency measuring...

Page 33: ...s only possible after appropriate configuration using ME iDC The other pins of the relevant subdevice can then no longer be used for digital input output n c n c FI_1 DIO_1 FI_3 DIO_3 FI_5 DIO_5 FI_7...

Page 34: ...cable red marked line is connected on to the IDC socket ST2 resp ST3 as shown in diagram 12 Diagram 12 Connecting the additional sockets ST2 ST3 20 pin IDC socket for ST2 and ST3 Pin Labeling ST2 3 P...

Page 35: ...7 to a 25 pin D Sub female connector E g for connecting the ME 63Xtend or ME UB series ME AK D2578 4000 Special connection cable for connection of the ME 63Xtend series via 25 pin D Sub female connect...

Page 36: ...n D2 Service address If a technical error should occur with your device please contact us at the following address Meilhaus Electronic GmbH Service Department Fischerstra e 2 D 82178 Puchheim Germany...

Page 37: ...ures 8 Frequency input output Programming 24 Wiring 18 Frequency measurement 18 25 H Hardware description 15 I Interrupt Programming 27 Wiring 19 Introduction 5 L Logic level matching 20 O Operation M...

Page 38: ...Rev 1 1E Manual ME 5001 Index Page 38 Meilhaus Electronic...

Reviews: