Rev. 1.1E
Manual ME-5001
Programming
Page 22
Meilhaus Electronic
Subdevice-Konfigurationen ME-5001
*Standard configuration
at shipment. The most recently selected
configuration in the ME-iDC is stored in a non-volatile memory on the
board, and is automatically loaded after a restart.
Depending on requirements, you can select from the following
operation modes
:
•
Single:
Individual values can be read or written in this operation
mode.
•
Interrupt:
For the interrupt handling in the bit-pattern change mode
(see chapter 4.2.1 starting on page 27).
Subdevice type…
…subtype
I/Os
ID of the
configuration
Subdevice 0 (DIO, FI)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Frequency input (FI)
Single
8 channels
1
Subdevice 1 (DIO, FO)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Frequency output (FO)
Single
8 channels
1
Subdevice 2 (DIO)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Subdevice 3 (DIO)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Subdevice 4 (DIO)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Subdevice 5 (DIO)
Digital input/output (DIO)
Single
8 bit
bi-directional
0*
Table 2: Subdevice configuration ME-5001