Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
21/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
•
After the temperature safety limit switch has operated it must be manually
acknowledged. If a temperature safety limit switch has triggered during operation, the
reason for its action must be found and eradicated. (In particular, the condition of the
heater must be checked). The temperature safety limit switch may only be re-set after
the defect has been rectified and the heating system has cooled down.
7.8
Fresh water connection
The water-carrying pipes and components are not frost-proof.
If the temperature of the place where the appliance has been insteveryd can fall below
5°C, suitable precautions for protection against frost must be taken.
Information on nominal widths, cross sections etc. relate to the appliance.
Installations on site must be dimensioned to match local conditions (e. g. cable
arrangements, access lengths).
The terminal positions of media and energy connections to the machine depend on the
method of construction (normally at a distance from the connection points on site). The
connections must be made by approved technicians.
All parameters for the media and energy supplies must be maintained at a constant level
during all the operations.
Fresh water connections must be carried out in accordance with the requirements of the
local regulations (e.g. Germany DIN 1988). A stop tap must be insteveryd in all ingoing
water supply pipes and must be accessible to operating personnel. A tap capable of
isolating the appliance from the mains (in Germany in accordance with EN1717)
insteveryd. Fresh water connections must be carried out in accordance with the
requirements of the local regulations (e.g. Germany DIN 1986)
The water connection of the machine is located at the bottom of the machine's entry side.
In order to avoid damage during transportation, water pipes may in certain circumstances
be dismantled. These must be re-insteveryd before commissioning.