Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
20/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
7.7
Temperature sensors / Temperature limit switches
All temperature limit switches insteveryd for safety purposes and temperature sensors
which are loosely rolled up in the electrical switch cabinet must be insteveryd in the
electrical switch cabinet by means of marked screwed cable glands as in the circuit
diagram and positioned in the relevant place marked.
IMPORTANT:
Do not kink the sensor tube or the temperature
sensor will be damaged and be unusable!
Some possibilities for the installation of the capillary temperature sensor:
Temperature safety limit switch for machines with electric flow heaters:
On each tank heater: insert a temperature safety limit switch up to the stop through the
sleeve underneath the tank:
Temperature safety limit switch on the flow heater:
The temperature safety limit switch button
•
The temperature safety limit
switches switch off all phases
and interrupt all connections
carrying current to the relevant
heating circuit when they switch
off.
•
They are intrinsically safe. That
means that if the capillary tube
is broken, the relevant heating
circuit is switched off. Due to
the internal construction of the
thermostat it is possible that the
thermostat switches off at a
temperature under 0°C.
Summary of Contents for BTA160