Operating Instructions Tray washing machine Modell BTA 160 / 240
Datei:BA_BTA_9668415_EN_2009-10.docx
9668415
22/48
W e reserv e the right to c hange ex ec ution and constr uction!
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
water-carrying pipes,
For example to grow the flow
control instrument.
It is possible to clean the dirt screens without turning off the
main water supply.
The water supply is automatically cut off when the lower
component in which the screen is located is unscrewed.
This enables the screen can be easily cleaned during
maintenance.
(This cut-off function can also be used as a stop-cock when
servicing the machine.)
Information on the water quantities, quality and temperatures needed can be found in the
installation plan.
The water quality must also comply with the requirements of the Commercial Dish-
Washing Association.
Most appliances are equipped with heat regeneration or with a heat pump. In order for
this equipment to operate at optimum efficiency the inlet temperature of the rinse water
supply must be maintained at a low a level as possible (ideally about 10°C). Water supply
at a higher temperature not only detracts from the efficiency of the heat regeneration and
the heat pump, but also impairs conditions relating to the appliance’s exhaust air.
If valves on the appliance are also controlled by fresh water, a minimum flow pressure is
necessary. See “Regulations and Standard Values” for the necessary pressures and
quantities.
7.9
Waste water connection
The waste water connection must be carried out in accordance with the requirements of
DIN 1986 and all applicable local regulations.
All discharge pipes for water from the machine must be
connected to the kitchen waste water system via an
adequately dimensioned odour trap.
When selecting materials for pipes, sealants etc, you must
bear in mind that the temperature of the water discharged
from the machine can be 70 - 75
°
C. Furthermore, the pH
values can lie between 3 and 12 depending on the nature
and concentration of the detergent; in other words, the
materials must be resistant to both acids and alkalis.
Connect waste pipes on site in accordance with the
instructions on the installation plan.
Summary of Contents for BTA160
Page 48: ......