MeiG_SLM320_Hardware Design Manual
MeiG Smart Technology Co., Ltd
61/89
and records the average current for 5
minutes
Band5 23dBm CH20450
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
558.57
Band5 23dBm CH20600
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
581.79
Band7 0dBm
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
174.21
Band7 10dBm
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
210.1
Band7 23dBm CH20800
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
690
Band7 23dBm CH21100
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
700
Band7 23dBm CH21400
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
710.5
Band8 0dBm
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
174.21
Band8 10dBm
The tested module carries out data
transmission and maintains for 5 minutes,
and records the average current for 5
minutes
214.3