MeiG_SLM320_Hardware Design Manual
MeiG Smart Technology Co., Ltd
57/89
Band4 CH20375
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
38.59
Band5 CH20525
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
37.46
Band5 CH20600
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
38.83
Band5 CH20450
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
37.32
Band5 CH20525
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
37.46
Band8 CH21750
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
39.3
Band8 CH21625
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
37.59
Band8 CH21500
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
37.88
TDD
The module is
powered on,
and the DRX
monitoring
period of the
idle state on
the network is
1.28s
Band40 CH39150
Under the condition of no data
transmission, the tested module
maintained for 10 minutes and recorded
the average current for 10 minutes.
38.58
Band40 CH39150
Under the condition of no data
transmission, the tested module
38.94