15
~ 900(minutes)
#410
#429
#448
#467
Step 3 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#411
#430
#449
#468
Step 4 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#412
#431
#450
#469
Step 5 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#413
#432
#451
#470
Step 6 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#414
#433
#452
#471
Step 7 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#415
#434
#453
#472
Step 8 time * 2
Default value :0, time 0
~ 900(minutes)
R/W
Y
#416
#435
#454
#473
Repeat start step * 3
Default value :2,
range:1~8
R/W
Y
#417
#436
#455
#474
Repeat end step * 4
Default value :0,
Range:0~99
R/W
Y
#418
#437
#456
#475
Multi-step control state * 5
Default value :0,
Range:0~99
R/W
Y
#552
Multi-step control execution
flag of CH1
~
CH8 * 6
Set 1-8 channels,
default value :B0000
R/W
Y
0:No multi-stage
control
R/W
Y
1: perform Multi-step
control
R/W
Y
* 1. #400 ~ #407, #419 ~ #426, #438 ~ #445, #457 ~ #464: temperature Settings for each channel
segment. The unit is determined according to each input type. When the mode is Celsius, the unit is
0.1
℃
; when the mode is Fahrenheit, the unit is 0.1
℉
.
* 2. #408 ~ #415, #427 ~ BFM434, #446 ~ #453, #465 ~ #472: execution time of each channel segment.
When running multi-step Settings, the first stage execution time of each channel cannot be set to 0.
* 3. #416, #435, #454, #473: the starting segment number that needs to be repeated when setting the
multi-step setting of each channel.
* 4. #417, #436, #456, #474: the termination number that needs to be repeated when setting the
multi-step setting of each channel. The end segment number must not be less than the start segment
number of the channel, otherwise an execution error will result.
* 5. #418, #437, #457, #475: set the number of repeats for each channel.
* 6. #552: multi-step set enabled. #552 is effective with 8 bits less, the multi-step set function of Bit0
control channel 1 is start, the multi-step setting function of Bit1 control channel 2 is started, and so on.
When the mark is 0, start multi-step setting; When the flag is 1, a multi-step setting is performed. When
the multi-step setting is executing, write 0 to stop the multi-step setting. When you write 1 again, the
multi-step setting will be reexecuted from the first step.
1.5.5 Alarm function setting
The setting contents of the alarm function of the buffer of MTC-04-NT (BFM) are shown in table 1-12.