Scope Mode
The MPQ2000 has a real time scope mode. In this mode the analyzer will display
voltages and current waveforms, unbalance vectors, harmonics, inter-harmonics and
harmonic direction.
The SCOPE screen can also be opened by pressing the SCOPE short cut key.
The SCOPE screen consists of 3 different screens.
1.
The SCOPE or WAVEFORM Screen.
This screen will display
snapshots
of the
Voltage
and
Currents Waveform
. This screen is
updated every few seconds.
Use the
UP /
DOWN arrow keys to scroll through the different phases.
The image can be frozen by arrowing over to the HOLD option and then pressing
the ENTER key.
In the HOLD mode the arrows can be used to zoom in and out of the waveform.
By pressing the WAVEFORM key in the HOLD mode a scan line will open. This
will allow you to view individual values throughout the waveform.