49
Within this screen the user can select the number of taps of the VT. The default number of taps is two.
If the user selects more than two taps then the user is also required to select which tap is desired to test
Since the connections are different that when testing CT, the MRCT is only capable of test ing VTs one
tap at a time.
After either selecting the number of taps or the individual tap selection, the ratio test is begun by
selecting the blue play button.
5.2 Winding Resistance
Selection of
Winding Resistance Test button from the test configuration screen will bring
the user to the following Winding Resistance Test screen.