Getting to Know Your AVANT REMsp 

 
Intended Use Statement: 
The Avant series of REM (Real Ear Measurement) devices measure sound levels directly in patient’s 
ears. They are used in the measurement and fitting of hearing aids for adults and children. These 
measurements can be done with or without the hearing instrument being worn. They are also used for 
hearing loss simulation. The REM can perform Live Speech Mapping (MedRx’s in-situ method for getting 
the fitting right the first time). These devices should be operated by trained professionals with education 
and/or training in the field of audiometry 
 
Indication For Use Statement: 
The Avant REM (Real Ear Measurement) devices are for use by professionals with education and/or 
training in the field of audiometry to evaluate the fitting of hearing aids and are used for hearing loss 
simulation in adults and children. 
 
The AVANT REMsp represents a new era of precision in-situ verification for your office. Compact yet 
rugged, this PC-Based system is USB powered and supports ANSI and IEC Real Ear tests. The software 
includes targets for 

DSL i/o

 5.0 and 

NAL-NL2

. The REMsp is an affordable, single probe device which 

utilizes MedRx’s in-situ method for getting the fitting right the 

first

 time, 

every

 time.  

 

 

The following section of this manual will familiarize you with the physical features and 
accessories of the REMsp system.  
 

The Avant REMsp is a device that is used in measuring the real-ear acoustical characteristics of hearing 
aids. The device performs measurements of real-ear acoustical characteristics of a hearing aid on a given 
human ear, and does comply with the International Standards ANSI S-3.46 and IEC 61669. 

 

Transducers and Accessories

 

Use the accessories provided with your AVANT REMsp. Use of unapproved accessories is not recommended. 

We strongly recommend utilizing the supplied 6 inch or 6 foot USB extension cable with your REMsp. Plug the 
USB extension cable into your computer as shown below. 

 

 

 

 

REMsp Box

 

Speaker Audio 

Cable  

Bluetooth Speaker 

 

 

 

Speaker Power 

Supply

 

USB Extension 

Cable - 6 foot

 

USB Extension 

Cable - 6 inch

 

 

 

 

 

 

 

 

Summary of Contents for Avant REMsp

Page 1: ...INSTALLATION MANUAL www medrx usa com...

Page 2: ...ation 5 Driver Installation 8 EMC Precautions 11 Safety 14 Cleaning 15 Limited Warranty 16 0086 www medrx usa com 1200 Starkey Rd 105 Largo FL 33771 U S A Toll Free 888 392 1234 727 584 9600 Fax 727 5...

Page 3: ...of precision in situ verification for your office Compact yet rugged this PC Based system is USB powered and supports ANSI and IEC Real Ear tests The software includes targets for DSL i o 5 0 and NAL...

Page 4: ...19 39 from the patient for normal use It is preferred to plug the speaker into the power supply but it may be powered by the internal battery The Bluetooth option is not used The speaker s power cable...

Page 5: ...arts 2 On the Setup screen choose Install Avant REM If the Setup program does not automatically start Press the Win R keys on the keyboard Type D Setup exe in the window where D is the drive letter as...

Page 6: ...important document defines the acceptable usage of the REM software After reading the Agreement click I accept Click Next 6 This screen indicates the location of the program files Click Next Note You...

Page 7: ...AVANT REMsp Installation Manual Effective Date 10 21 2016 7 8 Ready to Install Program Click Install 9 Wait while the InstallShield Wizard installs the Avant REM program 10 When the installation is co...

Page 8: ...commend utilizing the supplied 6 inch or 6 foot USB extension cable with your REMsp Plug the USB extension cable into your computer as shown above 2 Wait for the system to copy and install default dri...

Page 9: ...anced Options screen click Install Drivers 6 When this screen appears click Ok 7 If this window appears and all devices are Ready to use click Close Drivers installed successfully 8 If this warning sc...

Page 10: ...en the audio properties are configured properly during driver installation the Audio Tab will appear like the image on the left If not use the pull down lists to adjust the settings to match the image...

Page 11: ...eclaration electromagnetic emissions The Avant REMsp is intended for use in electromagnetic environment specific below The customer or the user of the Avant REMsp should assure that it is used in such...

Page 12: ...P 80 to 800 MHz d 2 33 P 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation dista...

Page 13: ...ut power of transmitter W Separation distance according to frequency of transmitter meters 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0 233 0 1 0...

Page 14: ...Storage temperature range at least from 0 C to 50 C All components with patient contact are made of bio compatible materials This device does not produce any adverse physiological effects Install the...

Page 15: ...not be re used by another patient 2 It is recommended that 70 Isopropyl Alcohol should be applied to a soft clean cloth or tissue not directly on the component to be cleaned The cloth should never be...

Page 16: ...greater than 100 F and water liquid damage Repair or replacement of the system as provided under this warranty is the sole and exclusive remedy of the purchaser MedRx shall not be liable for any cons...