ASP-I-MASPI-9 MedRx AVANT REMsp Installation Manual 
Effective Date: 10-21-2016 

  

15 

Symbols that may be used: 

 

 

 

 or SN 

 

 

 

 

Read the instruction 

manuals for safe usage  

of the device.  

(operating instructions) 

 

Indicates that the device 

serial number will follow 

 

 

Type B applied part.   

(Type B equipment) 

 

Manufacturer (MedRx) 

 

 

 

 

 

 

 

Authorized Representative 

in Europe 

 

Non-ionizing electromagnetic 

radiation

 

 

Special Disposal Required

 

 

Humidity 

Limitation 

 

 

 

 

 

 

 

Caution, General warning 

sign

 

 

Temperature limitation

 

 

Read the instruction 

manuals for safe usage  

of the device  

(operating instructions)

 

 

Class II equipment

 

 

 

 

 

 

 

 

Start (of action)

 

 

Stop (of action)

 

 

Percentile Setup

 

 

Calibration

 

 

 

 

 

 

 

 

 

Loudspeaker (Speaker)

 

 

Headphones

 

 

Microphone

 

 

Recording

 

 

 Recommended Procedures for Cleaning and Disinfection 
  

1.  Probe Tubes are single use components, and should not be re-used by another patient. 
2.  It is recommended that 70% Isopropyl Alcohol should be applied to a soft clean cloth or tissue, not 

directly on the component to be cleaned. The cloth should never be wet, just damp. A mild soapy 
water solution is an alternative cleaning liquid. 

3.  To ensure that cross contamination does not occur, use clean cloth or sealed Alcohol swabs for 

each device to be cleaned. 

4.  Wipe the surfaces of the probe microphone, black ear loop and headphone pads with the 70% 

Isopropyl Alcohol. Clean other transducers in the same way. 

Do not let 70% Isopropyl Alcohol or 

water enter the microphone sound inlet.

 

5.  The probe microphone cords and white device housing may also be wiped with 70% Isopropyl 

Alcohol. The speaker controls, headphone ear pads, head band and other components may be 
cleaned in a similar way. 

6.  Let all components that have been cleaned, thoroughly dry before use. 
7.  Cleaning of the computer should be performed using the methods suggested in the computer’s 

manual.  

Summary of Contents for Avant REMsp

Page 1: ...INSTALLATION MANUAL www medrx usa com...

Page 2: ...ation 5 Driver Installation 8 EMC Precautions 11 Safety 14 Cleaning 15 Limited Warranty 16 0086 www medrx usa com 1200 Starkey Rd 105 Largo FL 33771 U S A Toll Free 888 392 1234 727 584 9600 Fax 727 5...

Page 3: ...of precision in situ verification for your office Compact yet rugged this PC Based system is USB powered and supports ANSI and IEC Real Ear tests The software includes targets for DSL i o 5 0 and NAL...

Page 4: ...19 39 from the patient for normal use It is preferred to plug the speaker into the power supply but it may be powered by the internal battery The Bluetooth option is not used The speaker s power cable...

Page 5: ...arts 2 On the Setup screen choose Install Avant REM If the Setup program does not automatically start Press the Win R keys on the keyboard Type D Setup exe in the window where D is the drive letter as...

Page 6: ...important document defines the acceptable usage of the REM software After reading the Agreement click I accept Click Next 6 This screen indicates the location of the program files Click Next Note You...

Page 7: ...AVANT REMsp Installation Manual Effective Date 10 21 2016 7 8 Ready to Install Program Click Install 9 Wait while the InstallShield Wizard installs the Avant REM program 10 When the installation is co...

Page 8: ...commend utilizing the supplied 6 inch or 6 foot USB extension cable with your REMsp Plug the USB extension cable into your computer as shown above 2 Wait for the system to copy and install default dri...

Page 9: ...anced Options screen click Install Drivers 6 When this screen appears click Ok 7 If this window appears and all devices are Ready to use click Close Drivers installed successfully 8 If this warning sc...

Page 10: ...en the audio properties are configured properly during driver installation the Audio Tab will appear like the image on the left If not use the pull down lists to adjust the settings to match the image...

Page 11: ...eclaration electromagnetic emissions The Avant REMsp is intended for use in electromagnetic environment specific below The customer or the user of the Avant REMsp should assure that it is used in such...

Page 12: ...P 80 to 800 MHz d 2 33 P 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation dista...

Page 13: ...ut power of transmitter W Separation distance according to frequency of transmitter meters 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0 233 0 1 0...

Page 14: ...Storage temperature range at least from 0 C to 50 C All components with patient contact are made of bio compatible materials This device does not produce any adverse physiological effects Install the...

Page 15: ...not be re used by another patient 2 It is recommended that 70 Isopropyl Alcohol should be applied to a soft clean cloth or tissue not directly on the component to be cleaned The cloth should never be...

Page 16: ...greater than 100 F and water liquid damage Repair or replacement of the system as provided under this warranty is the sole and exclusive remedy of the purchaser MedRx shall not be liable for any cons...

Reviews: