Further background information and hints for lateralization settings

Lateral width ...  

Limitation - AlphaTrainer HOME:

You can only adjust the lateral width with the AlphaTrainer Professional. 

•  

Some clients may feel slightly uneasy when the lateral width is set to 180° (when experiencing latera-
lization for the 

fi

 rst time). Adjust this setting only with clients that express such a discomfort. With each 

training session you then increase the lateral width until reaching 180°. 

•  

This function allows you to analyze how well your clients can direct their attention towards the lateral 
movement and how well they can concentrate on their respective reading task: Slightly adjust the set-
tings for the lateral width. If the client responds to this adjustment and gets distracted from the reading 
task, the level of concentration is not at its best.

• 

In return, applying very small values for the lateral width allows you to analyze how well the spatial 
hearing of your client works. 

Auditory-visual synchronization ...  

• 

As soon as you change one of the settings for lateralization (hold times, transfer times) the synchro-
nicity is no longer in place. 

• 

This function should only be applied with clients that show dif

fi

 culties using the LCD shutter glasses 

in parallel to the auditory stimulation. After some training sessions you should reach a level of compe-
tence in your client that allows for continuous non-synchronized training 

Employment and settings for the LCD shutter glasses ...

Limitation - AlphaTrainer HOME:

With the AlphaTrainer HOME the shutter glasses can be used. With the AlphaTrainer Professional, 
the level of darkness intensity is scalable. 

• Note:

 The client should continue to wear his regular glasses underneath the LCD shutter glasses.

• 

Use the LCD shutter glasses only in a later stage of the training. The client should already be accusto-
med to the auditory training modes. 

Exception: 

  For clients with visual perception problems, the LCD shutter glasses should be used 

at starting at an early stage of training.

• 

The level of intensity for the LCD glasses should usually be set to 100%. If the client struggles with the 
reading process when applying the LCD glasses, temporarily reduce the level of darkening intensity. 
Rebuild it to 100% within a few weeks of training.

• Important: 

As with the auditory settings, ensure that you choose values comfortable for your client in 

order to keep him motivated for the training.

Lateralization for the coach ... 

• 

If you drove through lateral training daily in several training units with clients, have possibly the need 
to hear the language normally. For this purpose you can use the non-lateralization adapter. This sup-
presses the movement at the jack headset-phone, at which he is attached. The lateralization to client 
headphones remains unimpaired of it. 

• 

In order to use the adapter, you proceed as follows: 

1.  Pull the plug at the headphone cable out of the AlphaTrainer. 
2.  Put the non-lateralization plug into the device socket. 
3.  Put the plug at the headphone cable into the socket of the non-lateralization plug.

 Menu: Lateralization / lateral movement from side to side 

Summary of Contents for AlphaTrainer Home

Page 1: ...Manual for AlphaTrainer Professional AlphaTrainer Home...

Page 2: ...arted 9 4 2 Display 9 4 3 Functions in the main menu 10 4 4 General information on submenus 11 4 5 Special function keys 11 4 6 Menu Volume 12 4 7 Menu Lateralization lateral movement from side to sid...

Page 3: ...essing auditory and visual stimuli in the trainee By alternating between left and right the brain and its respective he mispheres are forced to acquire a higher level of performance and brain coordina...

Page 4: ...onsists of two essential cable sets 1 Connects CD player and or computer line out as input device line in for the AlphaTrainer 2 Connects the student microphone into MIC in of both the computer and th...

Page 5: ...f you use an AlphaTrainer Home and you also want to have access to the additional functions of the Alpha Trainer Professional please get in contact with the MediTECH or your domestic MediTECH represen...

Page 6: ...gainst wetness and humidity They or third could be injured In addition the device could be damaged effectively and strongly Caution Just use the plug power pack provided It was developed particularly...

Page 7: ...he AlphaTrainer The following diagram shows all elements of the AlphaTrainer which you can apply when using this lateral training device Navigation keys and enter key Menu selection keys Menu selectio...

Page 8: ...re allocated correctly to client s and trainer Attention In order to avoid dangers technical problems and disfunctions during the employment of the AlphaTrainer it is very important that you ensure th...

Page 9: ...he black rocker switch to the left on the back of the device After short time a welcome screen in the display appears on the front of the device 4 2 Display If this announcement is to be seen in the d...

Page 10: ...lasses only Synchronization of auditory and visual signals Audio settings Presettings for microphones and head phones Dummy head stereophony MCVF Multi Channel Voice fusion Mono Stereo Volume settings...

Page 11: ...y switch to the desired function The submenu opens and the corresponding options show on the display 2 If you are in a submenu press T9 to return to the upper menu 4 5 Special function keys Return to...

Page 12: ...example describes how to adjust the trainer s microphone volume 1 Press T2 over the corresponding symbol The symbol is now highlighted In the center of the display you now see the text relevant for ad...

Page 13: ...ck to the upper menu level Trainer Head phones Volume L Volume R Volume for the headphones of the trainer s settings per ear left right 1 T6 switch to desired submenu 2 T1 switch to left ear settings...

Page 14: ...volume for all other sources such as CD player MP3 player etc in the same fashion Do not rely on the numbers showing on the display xx xx as they serve only for orientation purpo ses Your decision sh...

Page 15: ...requirements Press T12 in order to increase the transfer time The values in the display will grow bigger and both eyeglass lenses will be open longer in parallel Press T15 in order to decrease the tra...

Page 16: ...T14 save settings Video hold time R Defines for how long the right lense of the LCD glasses stays open 1 T2 switch to Video submenu 2 T2 switchto video hold time R submenu 3 T15 decrease T12 increase...

Page 17: ...s for the LCD shutter glasses Limitation AlphaTrainer HOME With the AlphaTrainer HOME the shutter glasses can be used With the AlphaTrainer Professional the level of darkness intensity is scalable Not...

Page 18: ...find further information on this currently active component 2 Press T15 to scroll through the list 3 Continue to press T15 until the arrow is in front of the headphones you are currently using 4 Pres...

Page 19: ...switch to enhancement submenu 2 T12 increase T15 decrease 3 T14 save settings MCVF Multi Channel Voice Fusion Limitation HOME Special extended hearing training Frequency band training in which model v...

Page 20: ...ining With the MCVF function the corresponding bands are cut full length into two and or four thin strips High frequencies are on one strip low frequencies on the other Now half of the bands switch si...

Page 21: ...ss T15 T12 in order to scroll through the title list Files with the ending mp3 can be played The arrow in front of the first entry indi cates the first title to be played A small small box in front of...

Page 22: ...play You will be asked if you wish to apply that list or create a new one Press T5 to create a new list 2 Press T2 Thus you select the attached USB stick as the media source The files stored on the US...

Page 23: ...the AlphaTrainer 1 T3 switch to file selection 2 T5 to create a new list or 3 T8 to extend an existing list 4 follow example 2 starting from step 3 MP3create play list USB mass memory Allows you to cr...

Page 24: ...bey example 2 in this section example 2 It pro vides a MP3 Liste with files on an external USB stick with the change that you press in the step 1 T8 for no no new list Consider it particularly here th...

Page 25: ...ent T5 switch to delete client submenu 2 T5 to delete T8 to abort deletion process Auditory threshold Individual settings of the auditory threshold for volume definition here you can readjust the volu...

Page 26: ...fining a client group rather than an individual client please ensure to com plete the entry for first name date of birth and gender This is mandatory in order to be able to process data in and with Me...

Page 27: ...client is female T15 if your client is male You will find your selection in the display 19 Press T14 in order to save your entry and return to client data over view End of entry 20 Press T9 to return...

Page 28: ...your training selection 3 Press T15 until you found the first VCV word that you want to add to your training list 4 Press T14 in order to add the currently marked word into the word list 5 Repeat thes...

Page 29: ...hen ist to be seen to see individual word lists 2 T15 to select an individually created word list content is shown in the display 3 T9 to activate selected list for training Delete word group Delete a...

Page 30: ...ice in a sample 1 T3 switch to submenu 2 T15 off T12 on 3 T14 save settings Left right Only available with level Defines if the two items shall be presented on opposing ears or based upon the standard...

Page 31: ...order to perceive his VCV words 1 Select a word group predefined or individual and preset your training parameters as needed as described on the previous pages 2 Start the training sequence To do so p...

Page 32: ...wered at all 7 tasks minus 5 correct ones minus 1 repetition 1 Its own list was offered to the client which consisted of the words ebi edi efi eki and eti The word ebi was offered answered correctly f...

Page 33: ...ow marks the entry which you can change straight Press T12 and or T15 if you liked to change another entry 2 Press T14 in order to be able to change the current entry Date 3 In the lower part of the d...

Page 34: ...ement Announcement of current settings under over the symbols in a subme nu z B Volumes on out 1 T4 switch to the parameter display sub menu 2 T12 turn on T15 turn off 3 T14 save settings Free memory...

Page 35: ...urer contact details 1 T1 switch to information submenu 2 Press any key to return to help submenu Device version Shows the device type home or professional the current firmware version and the device...

Page 36: ...ear him on the identical side as the MP3 CD signal The microphone may be switched off or connected to the wrong socket Ve rify if the microphone is turned on Check i fit is connected to the right sock...

Page 37: ...dures on your own Please contact our service department to discuss the details of how to proceed Do you have further questions are you experiencing errors or problems when operating the AlphaTrainer C...

Page 38: ...ements can be bought in typical specialist shops or directly from MediTECH the contact details are in the back of this manual 5 2 Maintenance and storage 1 Make sure that only you switch off the devic...

Page 39: ...ce identification plate 2012 123XXX Manufacturer name and contact details Technical data regarding in and output voltage Prior to first connecting your power adapter ensure to mount the correct connec...

Page 40: ...dimensions 101 mm x 82 mm In operation Ambient temperature 5 C up to 40 C Relative air humidity 40 65 Air pressure 700 1060 hPa Storage and transportation Ambient temperature 20 C bis 50 C Relative a...

Page 41: ...well as an ear surrounding pair of headphones This way the client has the possibility to select his her preferred set of headphones MediTECH microphone Specially adapted dynamic microphone Jack 6 35...

Page 42: ...tions and problems around lateral training for the entire time in which you work with the device You can reach the telephone hotline at 49 0 5130 97778 0 Naturally you can also send in your questions...

Page 43: ..._____________________________________________________________________________ ___________________________________________________________________________________ ______________________________________...

Page 44: ...ort about experiances the the devide or the method Please contact us MediTECH Electronic GmbH Langer Acker 7 D 30900 Wedemark Germany Tel 49 0 51 30 9 77 78 0 Fax 49 0 51 30 9 77 78 22 Email service m...

Reviews: