Page 9 - 4
TA3H, TA3SH & TA3.5SH
9. Maintenance
9.8
ROPS
Check for:-
• Worn, damaged or missing mountings. If there is excessive movement or rattling during
operation the ROPS mountings must be checked and replaced if necessary.
• Loose or missing nuts, bolts and washers. Missing items must be replaced with those of the
same grade/specification. Bolts and nuts should be tightened to the correct torque.
• Cracks in the ROPS and its mountings.
• Paint peeling and corrosion. If necessary take corrective action.
If the machine has rolled over or been involved in an accident in which the ROPS could have
been damaged the ROPS must be replaced.
If you have any doubts regarding the integrity of the ROPS and for replacement parts consult
your Mecalac dealer.
9.9
Floor Plate Removal
To gain access to the battery, hydrostatic transmission pump and various other components it
will be necessary to remove the floor plate - Figure 9.3 refers
.
Figure 9.3 - Floor Plate Removal
1.
Floor plate bolts
PROCEDURE
1
To fit the lock bar remove the grip clip and pin from the bar.
2
Pivot the locking bar around until the holes in the bar are in line with the holes in rear
chassis bracket.
3
Re fit the pin through the holes and secure with the grip clip.
COV00224
1
Summary of Contents for TA3.5SH
Page 6: ...Table of Contents 4 TA3H TA3SH TA3 5SH Table of Contents...
Page 72: ...Page 7 10 TA3H TA3SH TA3 5SH 7 Standard Operating Procedures...
Page 76: ...Page 8 4 TA3H TA3SH TA3 5SH 8 Emergency Operating Procedures...
Page 114: ...Page 11 2 TA3H TA3SH TA3 5SH 11 Recovery...
Page 118: ...Page 13 2 TA3H TA3SH TA3 5SH 13 Glossary...
Page 119: ...TA3H TA3SH TA3 5SH Appendices 1 Appendices Appendix 1 Electrical Diagrams...
Page 126: ...Appendices 8 TA3H TA3SH TA3 5SH Appendices...
Page 127: ...TA3H TA3SH TA3 5SH Appendices 9 Appendices Appendix 2 Hydraulic Diagrams...
Page 132: ...Appendices 14 TA3H TA3SH TA3 5SH Appendices...
Page 134: ...Warranty 2 Warranty Certificate...
Page 135: ......