background image

 

Technical

 

Manual

 

Shutter

 

actuator

 

JAL

0X10X.01

 

 

 

 

MDT technologies GmbH  •  

51766 Engelskirchen  •  Papiermühle 1

 

 

Tel.: +49-2263-880  •  Fax: +49-2263-4588  • [email protected]  •  www.mdt.de 

33

 

 

The

 

communication

 

objects

 

are

 

shown

 

at

 

the

 

following

 

chart:

 

Number

 

Name

  

Length

  

Usage

Number

5

 

automatic

 

A

 

automatic

 

position

 

1

 

1

 

Bit

 

Call

 

of

 

the

 

first

 

automatic

 

position

 

at

 

block

 

A

 

6

 

automatic

 

A

 

automatic

 

position

 

2

 

1

 

Bit

 

Call

 

of

 

the

 

second

 

automatic

 

position

 

at

 

block

 

A

 

7

 

automatic

 

A

 

automatic

 

position

 

3

 

1

 

Bit

 

Call

 

of

 

the

 

third

 

automatic

 

position

 

at

 

block

 

A

 

8

 

automatic

 

A

 

automatic

 

position

 

4

 

1

 

Bit

 

Call

 

of

 

the

 

fourth

 

automatic

 

position

 

at

 

block

 

A

 

9

 

automatic

 

B

 

automatic

 

position

 

1

 

1

 

Bit

 

Call

 

of

 

the

 

first

 

automatic

 

position

 

at

 

block

 

B

 

10

 

automatic

 

B

 

automatic

 

position

 

2

 

1

 

Bit

 

Call

 

of

 

the

 

second

 

automatic

 

position

 

at

 

block

 

B

 

11

 

automatic

 

B

 

automatic

 

position

 

3

 

1

 

Bit

 

Call

 

of

 

the

 

third

 

automatic

 

position

 

at

 

block

 

B

 

12

 

automatic

 

B

 

automatic

 

position

 

4

 

1

 

Bit

 

Call

 

of

 

the

 

fourth

 

automatic

 

position

 

at

 

block

 

B

 

Chart

 

20:

 

communication

 

objects

 

automatic

 

function

 

 

The

 

communication

 

objects,

 

with

 

the

 

size

 

of

 

1

 

Bit,

 

can

 

be

 

allocated

 

arbitrary

 

to

 

the

 

group

 

addresses.

 

By

 

calling

 

one

 

of

 

the

 

communication

 

objects,

 

the

 

deposited

 

values

 

for

 

the

 

automatic

 

function

 

are

 

called.

 

It

 

is

 

possible

 

to

 

move

 

all

 

channels

 

of

 

one

 

shutter

 

actuator

 

to

 

their

 

parameterized

 

values

 

with

 

only

 

one

 

command,

 

but

 

also

 

to

 

move

 

only

 

one

 

channel.

 

This

 

happens

 

in

 

according

 

to

 

the

 

parameterization,

 

which

 

was

 

made

 

for

 

the

 

individual

 

channel

 

at

 

the

 

subitem

 

automatic

 

function

 

(have

 

a

 

look

 

at

 

4.7.1).

 

To

 

move

 

more

 

channels

 

to

 

the

 

same

 

time

 

to

 

a

 

specific

 

value,

 

you

 

have

 

to

 

choose

 

the

 

same

 

blocks

 

for

 

these

 

channels

 

and

 

set

 

the

 

same

 

values

 

for

 

this

 

automatic

 

positions.

 

 
 

4.8

 

Alert

 

functions/

 

superior

 

functions

 

 

The

 

shutter

 

actuator

 

can

 

react

 

to

 

specific

 

weather

 

situations

 

and

 

introduce

 

several

 

reactions

 

for

 

this

 

channel

 

to

 

protect

 

the

 

shutters/blinds

 

by

 

using

 

the

 

alarm

 

function.

 

Additional

 

reactions

 

on

 

a

 

bus

 

power

 

breakdown

 

or

 

a

 

bus

 

power

 

return

 

can

 

be

 

defined.

 

The

 

alarm

 

functions

 

can

 

be

 

activated

 

or

 

deactivated

 

for

 

every

 

several

 

channel.

 

The

 

signals

 

for

 

the

 

alarms

 

can

 

be

 

recovered

 

of

 

a

 

KNX

 

weather

 

station.

 

Now

 

the

 

shutter

 

actuator

 

is

 

able

 

to

 

evaluate

 

these

 

signals

 

and

 

assemble

 

them

 

according

 

to

 

the

 

parameterization.

 

The

 

following

 

Illustration

 

shows

 

the

 

activation

 

of

 

the

 

alert

 

functions

 

for

 

a

 

channel:

 

 

Illustration

 

18:

 

Alert

 

functions

 

 

If

 

the

 

alert

 

function

 

is

 

activated

 

for

 

a

 

channel,

 

at

 

the

 

left

 

drop

down

 

menu

 

appears

 

a

 

subitem

 

(channel

 

X:

 

Alarms),

 

in

 

which

 

the

 

following

 

parameterization

 

can

 

ensue.

 

Summary of Contents for JAL-01UP.01

Page 1: ...51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 12 2011 Technical Manual MDT Shutter Actuator JAL 0206 01 JAL 0410 01 JAL 0810 01 JAL 0410D 01 JAL 0810D 01 JAL...

Page 2: ...objects per channel 12 3 5 Default settings of the communication objects 14 4 Reference ETS Parameter 16 4 1 Channel selection 16 4 1 1 Shutter 17 4 1 2 Blinds 17 4 2 Time for movement 18 4 2 1 Measur...

Page 3: ...Subitem automatic function 31 4 7 2 Automatic blocks 32 4 8 Alert functions superior functions 33 4 8 1 Subitem alert functions 34 4 8 1 Order of alarms 35 4 8 2 Alarm types 36 4 8 3 Periodic observa...

Page 4: ...600W JAL 01UP 01 Shutter Actuator 1 fold 230VAC 6A flush mounted fitting o 1 fold for shutter motors up to 300W 2 2 Usage possible applications The Shutter Actuator actuates shutters as well as blind...

Page 5: ...ies GmbH 51766 Engelskirchen Papierm hle 1 Tel 49 2263 880 Fax 49 2263 4588 knx mdt de www mdt de 5 2 3 Exemplary Circuit diagrams Illustration 1 exemplary circuit diagram shutter actuator 4 fold Illu...

Page 6: ...DC Every channel of the MRDC device contains of two status LEDs the first one for an activated run up command and the second one for an activated move down command By using the four buttons you can ac...

Page 7: ...irection and a switch on delay or a switch off delay for the motor Also you can restrict the driving area or move the shutter by giving absolutely driving commands By using scene or automatic function...

Page 8: ...fter driving to reference limitation of driving area active not active lower limit 0 100 upper limit 0 100 central objects reaction of the central objects for every channel activatable deactivatable s...

Page 9: ...t type Shutter actuator Medium Type Twisted Pair TP Product name addicted to the used type e g JAL 0810 01 shutter actuator 8 fold 8TE 10A Order number addicted to the used type e g JAL 0810 01 2 7 St...

Page 10: ...annel A has the objects 13 to 32 and the channel B the objects 33 to 52 and so on 3 2 Global communication objects For every single channel you can justify whether it shall react on the global objects...

Page 11: ...block A the numbers 5 to 8 are reserved and for the channel B the numbers 9 to 12 are reserved The following illustration shows the communication objects for the both automatic blocks Illustration 5...

Page 12: ...el The numbers follows on the global objects and the objects for the automatic function Therefore these objects have the numbers from 13 So the channel A has the numbers from 13 to 32 and the channel...

Page 13: ...PT 5 001 In Write 20 Status actual position Shows the actual position DPT 5 001 Out Read 21 Status actual position of blinds Shows the actual position of blinds DPT 5 001 Out Read 22 Act Position vali...

Page 14: ...Automatic B Automatic position 3 1 Bit Low X X 12 Automatic B Automatic position 4 1 Bit Low X X 13 Channel A Shutter up down 1 Bit Low X X 14 Channel A Blinds up down stop 1 Bit Low X X 14 Channel A...

Page 15: ...Block 1 Bit Low X X 20 next channel Chart 5 standard settings communication objects You can see the default values for the communication objects from the upper chart According to requirements the prio...

Page 16: ...xt Dynamic range default value comment Channel A D H not active Shutter Blinds Operating mode of the channel Chart 6 possible settings for the channel selection Every of the 1 to 8 available channels...

Page 17: ...tical communication between KNX devices The communication object Blinds up down stop is used to adjust the blinds By calling this object the current movement of the shutter is simultaneous stopped 4 1...

Page 18: ...ble to parameterize the Actuator individually for almost every shutter blind To be sure that the movement function works properly you have to parameterize these times carefully If the channel is selec...

Page 19: ...switch off delay for motors which have time lag after set off Position of blinds at end of driving 0 100 50 only at shutter sets the position of blinds after driving the shutter Short time operation...

Page 20: ...s possible to adjust the step range in a way so that the blinds drive from one final position to the other in a specific number of steps For this way of blind movement you have to set the step time fo...

Page 21: ...ly 4 2 6 Switch on Switch off delay motor Some motors can not bring the full power at the moment of switching it on but first after some milliseconds The time which the motor needs to get the full pow...

Page 22: ...tion after a driving to reference Status objects not active active enables the status objects Status object for visualization Status actual direction Status of movement adjusts the status object for t...

Page 23: ...the reference run by the setting drive to former position Through the setting no reaction the shutter actuator lets the shutter blinds at the position which was reached after the end of the reference...

Page 24: ...utter blinds 4 3 5 Status objects for Visualization The 1 bit status object Status of movement shows that a movement of these shutters blinds is active right now A running movement is indicated by a l...

Page 25: ...n object is displayed for the associated channel Number Name Length Usage 24 Drive to limitation 1 Bit drives to the lower upper limit Chart 13 communication object limitation You set new limits for t...

Page 26: ...Stop 1 Bit stop function for every channel 3 absolute Position 1 Byte absolute command for height at every channel 4 absolute position of blinds 1 Byte absolute command for opening angle of blinds at...

Page 27: ...s activated for this channel the according scene menu is shown At this menu the single scenes can be activated and values scene numbers and the memory function on off can be set Scenes get activated b...

Page 28: ...ave the names A H Every of the 8 scenes can get one of the possible 64 scene numbers The following illustration shows the setting options at the sub item scene channel X scene for the scenes A D and a...

Page 29: ...of this scene This reaction contains a command for an absolute height 0 100 for this channel or additional an absolute position of blinds at a shutter channel see also Chart 17 Every channel can reac...

Page 30: ...x03 3 0x83 131 5 0x04 4 0x84 132 6 0x05 5 0x85 133 7 0x06 6 0x86 134 8 0x07 7 0x87 135 9 0x08 8 0x88 136 10 0x09 9 0x89 137 11 0x0A 10 0x8A 138 12 0x0B 11 0x8B 139 13 0x0C 12 0x8C 140 14 0x0D 13 0x8D...

Page 31: ...same time through the automatic function for example drive the blinds as well as the shutter and change the opening angle of the blinds The following Illustration shows the activation of the automatic...

Page 32: ...ynamic range automatic function At the subitem for the automatic function you can depose values for 4 different automatic calls The values are absolute values which the channel accepts at the call of...

Page 33: ...objects the deposited values for the automatic function are called It is possible to move all channels of one shutter actuator to their parameterized values with only one command but also to move onl...

Page 34: ...Subitem alert functions If the alert function is activated you can make the following parameterization at the appeared subitem The following illustration shows the drop down menu for the alert functio...

Page 35: ...ock Rain Frost Block Rain Wind Frost sets the priority of the alarms Chart 21 Order of alarms If there are two or more alarms activate to the same time the shutter actuator will evaluate the alarms ac...

Page 36: ...ic observation of the rain alarm setting 0 deactivates the periodic observation Action only when rain alarm is activated no action drive to top drive to bottom Action when rain alarm gets active Frost...

Page 37: ...0 to 120min whereby the setting 0 min sets the periodic observation off The communication object for the respectively alarm must get a signal during the parameterized time otherwise the alarm causes a...

Page 38: ...ion when bus power down up can assign the shutter actuator an action how he shall react to faults of the bus power The following chart shows the dynamic range for this parameter ETS text Dynamic range...

Page 39: ...or every channel by a separately subitem When the block function was activated for a channel a new subitem appears under the according channel called channel X block at the drop down menu The followin...

Page 40: ...rol not active active with activation of the object block universal mode the manual control gets blocked Block up down movement not active active with activation of the object block universal mode the...

Page 41: ...configure the blocking process on your own by using the parameter Blocking universal mode Therefore 5 different options are available Block manual control blocks the manual control at the device for t...

Page 42: ...ion objects per channel Page 12 Illustration 7 Channel selection Page 16 Illustration 8 Time for movement Shutter Page 18 Illustration 9 Time for movement Blinds Page 18 Illustration 10 Objects absolu...

Page 43: ...age 19 Chart 10 Setting range absolute position Page 22 Chart 11 Communication objects absolute position Page 22 Chart 12 Dynamic range limitation Page 25 Chart 13 Communication object limitation Page...

Page 44: ...ge can occur danger for humans animals or material assets Do not let the packaging lying around careless plastic foil bags etc can be a dangerous toy for kids 6 2 Routine disposal Do not throw the was...

Page 45: ...After bus voltage failure or recovery the position of the shutter is selected in dependence on the parameterization The Shutter Actuator is available as modular installation device surface mounted de...

Page 46: ...mechanical 1 000 000 1 000 000 1 000 000 max fuse per channel 16A 10A 10A permitted wire gauge Screw terminal 2 5mm 2 5mm 2 5mm KNX busconnection terminal 0 8mm 0 8mm 0 8mm Operation temperature range...

Reviews: