T
ROUBLESHOOTING
Contact MDG, if symptoms are not listed, or if the provided solutions fail to resolve the issue.
Table 2: Symptoms and Solutions
Symptoms
Probable Causes and Suggested Actions
The generator does not switch On
Verify that AC power cord is properly connected on
both ends.
Check the fuse or the breakers of your VAC entry.
The wattage of the generator is 1480 W.
Verify the AC voltage on the power cord. 100~250
VAC.
The generator does not produce fog
Verify that the Unit is ON («
CONTROL
UNIT
ON
»)
Verify that the UNIT is READY («
STATUS
STATE
=
READY
»)
The generator needs approximately eight (8) minutes
to be ready.
Verify that the Unit is not in a FAIL state
(«
STATUS
STATE = FAIL
»)
If Yes, check the symptoms below
Verify the communication mode
(«
INTERFACE
COMM
.
»)
You cannot control the generator locally if you are in
DMX mode, and vice-versa.
If you are in DMX mode:
-
Verify the cable
-
verify the DMX Start address and the channels
If you are in Network mode:
-
Verify the cable
-
Verify the Node status
-
Verify the RDM ID number
-
Verify the Universe parameters and the DMX Start
Address
… ∕…