LED Status:

 

 

FOG  Green  LED  indicates  that  the  generator  is 
producing fog.

 

 

DELAY  Yellow  LED  indicates  that  the  delay  is 
activated and won’t  produce fog  until it  is  turned 
off.

 

 

FLUID  VALVE  Green  LED  indicates  that  the  fluid 
solenoid  valve  is  on  and  should  turn  on  and  off 
with the FOG LED.

 

 

CO2  VALVE  Green  LED  indicates  that  the  liquid 
CO2 solenoid valve is on

 

Fog Output Delay:  

Delay of 3 to 30 seconds. Allowing to cool down the 
cold  chamber  of  the  Generator  before  producing 
low fog.

 

Fog Output adjustment: 

Pressure regulator & Gauge 

Maximum Operating 

pressure 4.14 bar (60 psi)

 

Main Power 

switch

 

Power Cord 

115 or 230 VAC, 50/60 Hz

 

Operating Pressure: 

Low pressure: liquid CO

2

 input, at 1500 kPa (225 psi) 

High pressure: liquid CO

2

 input, at 

6000 kPa (875 psi) 

 

Pressure Switch: 

Upward position will pressurize 

the Fluid Reservoir. 

Downward position will 

depressurize allowing to refill 

the Fluid

 

reservoir.

 

Detacheable standard remote control 

See next page

 

Summary of Contents for ICE FOG Compack

Page 1: ...td M A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ICE FOG Com...

Page 2: ...ICE FOG CompackTM User Guide120818 Rev B a 2 19 Intentionally left blank...

Page 3: ...available under request for low pressure refrigerated liquid Carbon Dioxide low pressure cryogenic L CO2 Dewar We hope it will bring you long hours of satisfaction This product is available in many ve...

Page 4: ...hree types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT...

Page 5: ...valve is on Fog Output Delay Delay of 3 to 30 seconds Allowing to cool down the cold chamber of the Generator before producing low fog Fog Output adjustment Pressure regulator Gauge Maximum Operating...

Page 6: ...Connector Green LED indicates that the Generator is READY to operate Fog switch with a Green LED indicator Power switch with the Red LED HEAT yellow LED indicator 1 The LED turns on and off from time...

Page 7: ...es Optional Accessories DMX M35AX Optional 2 Channel DMX Interface IF35 RCT Optional Remote Control Timer Output Fog Hose 2 5 m 8 long 13 cm 5 diameter Different lengths available Low Fog Output Front...

Page 8: ...de L CO2 with Dip Tube or Siphon Use only carbon dioxide cylinder equipped with a dip siphon tube allowing the discharge of liquid CO2 Refrigerated Low pressure Liquid Carbone Dioxide L CO2 Container...

Page 9: ...ng the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will tu...

Page 10: ...ck panel of the generator 7 Unscrew the brass cap 8 Pour the MDG Low Fog Fluid until it reaches the inside bottom of the opening Avoid overfilling 9 Screw back the closure and make sure it is hand tig...

Page 11: ...ocated on the back panel or unplug the generator Never install above people These Low Fog Generators must be installed on a stable and horizontal surface Do not operate at less than 2 meters 6 5 ft fr...

Page 12: ...ments WARNING Only use High pressure Liquid Carbon Dioxide L CO2 with Dip Tube or Siphon If you have ordered the LP version only use low pressure refrigerated liquid Carbon Dioxide L CO2 Dewar contain...

Page 13: ...emission on the remote Switch off the pressure switch on the main panel Close the valve of the high pressure Liquid CO2 bottle or refrigerated low pressure liquid L CO2 valve of the Dewar Power off th...

Page 14: ...R BY TURNING OFF THE PRESSURE SWITCH LOCATED ON THE MAIN PANEL OF THE GENERATOR To fill the fluid reservoir Always turn off the low fog emission on the remote Switch off the pressure switch on the mai...

Page 15: ...ize 0 5 4 5 microns CO2 running time High pressure version 23 kg 50 lb canister 17 minutes Low pressure version 180 L 48 US gallon canister DEWAR 120 minutes Warm up time maximum 8 10 minutes Fluid ty...

Page 16: ...ICE FOG CompackTM User Guide120818 Rev B a 16 19 TECHNICAL DIMENSIONS...

Page 17: ...DG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for...

Page 18: ...ICE FOG CompackTM User Guide120818 Rev B a 18 19 DECLARATION OF CONFORMITY...

Page 19: ...ICE FOG CompackTM User Guide120818 Rev B a 19 19 NOTE...

Reviews: