SHUT
DOWN
PROCEDURE
A generator must never be shut down while making Fog.
To power off a generator the following sequence must be observed:
Always turn off the low fog emission on the remote,
Switch off the pressure switch on the main panel
Close the valve of the high pressure Liquid CO
2
bottle or refrigerated low pressure
liquid L-CO
2
valve of the Dewar
Power off the Unit on the remote
Power off the Low Fog generator by switching off the “MAIN POWER SWITCH“
If not in use for a long period, always depressurize the line between the generator
and the high pressure Liquid CO
2
bottle.