TECHNICAL DATA 

 

Model  

ICE FOG Compack 

Fluid consumption  

0.035 L (1.05 oz) 

(per minute at full output) 

Liquid CO

2

 type  

High pressure version: Non-refrigerated  

 

Low pressure version: Refrigerated 

Liquid CO

2

 consumption  

High pressure version:1.35 kg (3 lb) at 6000 kPa (875 psi) 

(per minute) 

Low pressure version: 3 L (6.8 lb) at 1500 kPa (225 psi) 

Reservoir capacity  

2.5 L (0.66 US gallon) 

Fog colour  

Pure white 

Particle size  

0.5-4.5 microns 

CO

2

 running time  

High pressure version: 

 

23 kg (50 lb), canister = 17 minutes 

 

Low pressure version:  

 

180 L (48 US gallon), canister (DEWAR) = 120 minutes 

Warm-up time (maximum)  

8-10 minutes 

Fluid type MDG  

Low Fog Fluid 

(M.S.D.S. available on request) 

Operating voltage  

115 or 230 VAC, 50/60 Hz 

Power consumption  

1,450 W 

Dimensions  

Total length  1.15 m (45 1/8“) 

 

Operating length  1.08 m (42 3/8”) 

 

Width   63.5 cm (25”) 

 

Height  82.5 cm (32 1/2”) 

Weight  

91 kg (200 lb) 

Approval  

CE approved,  

 

CSA and UL pending 

Included  

Remote control  

 

8 m (26 ft) 5-pin XLR extension cable  

 

2.5 m (8 ft) long x 13 cm (5 in) diameter fog output 

 

3 m (10 ft) insulated liquid CO

2

 input hose with gauge.  

 

Summary of Contents for ICE FOG Compack

Page 1: ...td M A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ICE FOG Com...

Page 2: ...ICE FOG CompackTM User Guide120818 Rev B a 2 19 Intentionally left blank...

Page 3: ...available under request for low pressure refrigerated liquid Carbon Dioxide low pressure cryogenic L CO2 Dewar We hope it will bring you long hours of satisfaction This product is available in many ve...

Page 4: ...hree types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT...

Page 5: ...valve is on Fog Output Delay Delay of 3 to 30 seconds Allowing to cool down the cold chamber of the Generator before producing low fog Fog Output adjustment Pressure regulator Gauge Maximum Operating...

Page 6: ...Connector Green LED indicates that the Generator is READY to operate Fog switch with a Green LED indicator Power switch with the Red LED HEAT yellow LED indicator 1 The LED turns on and off from time...

Page 7: ...es Optional Accessories DMX M35AX Optional 2 Channel DMX Interface IF35 RCT Optional Remote Control Timer Output Fog Hose 2 5 m 8 long 13 cm 5 diameter Different lengths available Low Fog Output Front...

Page 8: ...de L CO2 with Dip Tube or Siphon Use only carbon dioxide cylinder equipped with a dip siphon tube allowing the discharge of liquid CO2 Refrigerated Low pressure Liquid Carbone Dioxide L CO2 Container...

Page 9: ...ng the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will tu...

Page 10: ...ck panel of the generator 7 Unscrew the brass cap 8 Pour the MDG Low Fog Fluid until it reaches the inside bottom of the opening Avoid overfilling 9 Screw back the closure and make sure it is hand tig...

Page 11: ...ocated on the back panel or unplug the generator Never install above people These Low Fog Generators must be installed on a stable and horizontal surface Do not operate at less than 2 meters 6 5 ft fr...

Page 12: ...ments WARNING Only use High pressure Liquid Carbon Dioxide L CO2 with Dip Tube or Siphon If you have ordered the LP version only use low pressure refrigerated liquid Carbon Dioxide L CO2 Dewar contain...

Page 13: ...emission on the remote Switch off the pressure switch on the main panel Close the valve of the high pressure Liquid CO2 bottle or refrigerated low pressure liquid L CO2 valve of the Dewar Power off th...

Page 14: ...R BY TURNING OFF THE PRESSURE SWITCH LOCATED ON THE MAIN PANEL OF THE GENERATOR To fill the fluid reservoir Always turn off the low fog emission on the remote Switch off the pressure switch on the mai...

Page 15: ...ize 0 5 4 5 microns CO2 running time High pressure version 23 kg 50 lb canister 17 minutes Low pressure version 180 L 48 US gallon canister DEWAR 120 minutes Warm up time maximum 8 10 minutes Fluid ty...

Page 16: ...ICE FOG CompackTM User Guide120818 Rev B a 16 19 TECHNICAL DIMENSIONS...

Page 17: ...DG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for...

Page 18: ...ICE FOG CompackTM User Guide120818 Rev B a 18 19 DECLARATION OF CONFORMITY...

Page 19: ...ICE FOG CompackTM User Guide120818 Rev B a 19 19 NOTE...

Reviews: